{"schema_version":"1.0","package_type":"agent_readable_article","generated_at":"2026-05-31T04:16:25+00:00","article":{"id":8621,"slug":"how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event","title":"故障後の変流器の減磁方法は？","url":"https://voltgrids.com/ja/blog/how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event/","language":"ja","published_at":"2026-04-24T02:06:01+00:00","modified_at":"2026-05-11T02:15:02+00:00","author":{"id":1,"name":"Bepto"},"summary":"変流器の消磁手順をマスターし、故障発生後の保護リレーの精度を回復します。このテクニカル・ガイドでは、残留磁束の物理について説明し、ステップ・バイ・ステップのフィールド消磁手順を提供し、変電所の信頼性を確保し、高圧電力系統の危険なコア飽和を防止するための一般的なメンテナンスの間違いを特定します。.","word_count":373,"taxonomies":{"categories":[{"id":159,"name":"カレント・トランス(CT)","slug":"current-transformerct","url":"https://voltgrids.com/ja/blog/category/instrument-transformer/current-transformerct/"},{"id":146,"name":"計器用変圧器","slug":"instrument-transformer","url":"https://voltgrids.com/ja/blog/category/instrument-transformer/"}],"tags":[{"id":280,"name":"消磁","slug":"demagnetization","url":"https://voltgrids.com/ja/blog/tag/demagnetization/"},{"id":190,"name":"中電圧","slug":"medium-voltage","url":"https://voltgrids.com/ja/blog/tag/medium-voltage/"},{"id":191,"name":"信頼性","slug":"reliability","url":"https://voltgrids.com/ja/blog/tag/reliability/"},{"id":268,"name":"残留フラックス","slug":"residual-flux","url":"https://voltgrids.com/ja/blog/tag/residual-flux/"},{"id":189,"name":"トラブルシューティング","slug":"troubleshooting","url":"https://voltgrids.com/ja/blog/tag/troubleshooting/"}]},"media_links":[{"type":"video","provider":"YouTube","url":"https://youtu.be/O5rq9JKhXho","embed_url":"https://www.youtube.com/embed/O5rq9JKhXho","video_id":"O5rq9JKhXho"},{"type":"audio","provider":"SoundCloud","url":"https://soundcloud.com/bepto-247719800/how-to-perform-a/s-rNOotD1Sakf?si=50dff66b8a054446887aa6f8e04bda47\u0026utm_source=clipboard\u0026utm_medium=text\u0026utm_campaign=social_sharing","embed_url":"https://w.soundcloud.com/player/?url=https://soundcloud.com/bepto-247719800/how-to-perform-a/s-rNOotD1Sakf?si=50dff66b8a054446887aa6f8e04bda47\u0026utm_source=clipboard\u0026utm_medium=text\u0026utm_campaign=social_sharing\u0026auto_play=false\u0026buying=false\u0026sharing=false\u0026download=false\u0026show_artwork=true\u0026show_playcount=false\u0026show_user=true\u0026single_active=true"}],"sections":[{"heading":"はじめに","level":0,"content":"![LDJ-10(Q)-210 現在の変圧器 10kV 屋内エポキシ樹脂- 5-1250A 複数の巻上げ 0.2S 0.5S 5P10 クラス 12 42 75kV 絶縁材のコンパクト デザイン GB1208 IEC60044-1](https://voltgrids.com/wp-content/uploads/2026/01/LDJ-10Q-210-Current-Transformer-10kV-Indoor-Epoxy-Resin-5-1250A-Multi-Winding-0.2S-0.5S-5P10-Class-12-42-75kV-Insulation-Compact-Design-GB1208-IEC60044-1.jpg)\n\n[カレント・トランス(CT)](https://voltgrids.com/ja/product-category/instrument-transformer/current-transformerct/)\n\n中電圧配電システムで故障が発生すると、ブレーカーが落ちるだけではなく、現在の変圧器コア内に目に見えないが危険な遺産が残る可能性がある： **残留磁気**. **故障またはDCオフセット過渡現象の後にCTコアに捕捉された残留磁束は、電磁誘導精度を直接劣化させ、コアの早期飽和を引き起こし、次の故障時に誤った保護リレー動作や危険なアンダーリーチを引き起こす可能性があります。.** 変電所の信頼性を担当する電気エンジニアや保守チームにとって、CT コアを正しく消磁する方法を知ることは、オプションの保守知識ではなく、最前線の保護システムの完全性タスクです。この記事では、残留磁束の物理学、段階的な現場消磁手順、および CT コアがそもそも残留磁束の影響を受けやすいかどうかを判断する選択基準について詳しく説明します。."},{"heading":"目次","level":2,"content":"- [残留フラックスとは何か、なぜCTコアに形成されるのか？](#what-is-residual-flux-and-why-does-it-form-in-ct-cores)\n- [残留磁気はCTインダクションの性能と信頼性にどのような影響を与えますか？](#how-does-residual-magnetism-affect-ct-induction-performance-and-reliability)\n- [変流器の磁界減磁方法は？](#how-do-you-perform-a-field-demagnetization-procedure-on-a-current-transformer)\n- [中電圧 CT の減磁を失敗させる一般的な間違いとは？](#what-are-common-mistakes-that-cause-demagnetization-to-fail-in-medium-voltage-cts)"},{"heading":"残留フラックスとは何か、なぜCTコアに形成されるのか？","level":2,"content":"![粒方珪素鋼CTコアの詳細なクローズアップ図。この画像は、電流が除去された後、小さな磁区の矢印がほぼ一直線に並んだ内部結晶粒構造を示しており、コア内部に閉じ込められた高い残留磁束密度（Br）を視覚的に表している。このコアは、ケーブルや巻線が設置された大型の工業用電気パネルの一部であり、残留磁気の原因となった故障電流が発生したことを示している。.](https://voltgrids.com/wp-content/uploads/2026/04/CT-Core-with-Remaining-Residual-Flux-1024x687.jpg)\n\n残留フラックス付きCTコア\n\n残留磁束（残留磁気または残留磁束とも呼ばれる）とは、磁化力が除去された後にCTコアの粒方位珪素鋼構造の内部に閉じ込められたままの磁束密度のことである。なぜ残留磁束が形成されるのかを理解するには、以下の点を簡単に説明する必要があります。 [b-hヒステリシスループ](https://voltgrids.com/ja/blog/understanding-ct-b-h-magnetization-curve/) これはすべての強磁性コアの挙動を支配している。.\n\nCTが著しいDCオフセット成分を持つ故障電流を経験すると、一次電流はゼロ付近で対称的に振動しません。その代わりに、ヒステリシス曲線に沿って磁束密度の高い領域にコア磁束を駆動します。故障が解消され、電流が突然ゼロに低下した場合（サーキットブレーカーの遮断中に起こるような場合）、コアはゼロ磁束に戻りません。のままです。 **残留磁束密度（Br）**, に達することがある。 **[飽和磁束密度60-80%](https://ieeexplore.ieee.org/document/7981358)[1](#fn-1) (ビーサット)**.\n\nCTコア・リマネンスの主な技術的特徴：\n\n- **芯材の感度：** 高精度のCTに使用される）粒方珪素鋼は透磁率が高いが、残留磁化も高い。ニッケル-鉄合金コアはさらに高い残留磁化レベルを示す。.\n- **エアギャップ・コア：** で設計されたCTである。 [コア内の意図的なエアギャップ（IEC 61869-2によるTPYおよびTPZクラス）](https://webstore.iec.ch/publication/5964)[2](#fn-2) エアギャップが磁気リセット機構を提供するためである。.\n- **イベントを誘発する：** DCオフセット故障電流、CT二次側開回路事象、および試験後の不適切な消磁は、著しい残留磁束蓄積の3つの主な原因である。.\n\n| コア・タイプ | 残留レベル | IECクラス | 代表的なアプリケーション |\n| 粒状Si鋼（エアギャップなし） | 60-80% Bsat | 5P、10P、TPS | 標準保護CT |\n| ニッケル鉄合金（エアギャップなし） | 最大90% Bsat | クラスX、TPS | 高感度差動保護 |\n| ギャップドコア（小さなエアギャップ） |  | ティーピーワイ | オート・リクロース・プロテクション・スキーム |\n| 大型エアギャップ・コア | ~0% Bsat | ティーピーゼット | 高速保護、過渡性能 |\n\nスイッチギア・パネルに取り付けられているコアの種類によって、残留磁気のリスク・プロファイルが直接決定され、消磁手順が定期的に必須であるか、単なる予防措置であるかが決まります。."},{"heading":"残留磁気はCTインダクションの性能と信頼性にどのような影響を与えますか？","level":2,"content":"![残留磁気がCTの利用可能な磁束スイングを減少させ、コアの早期飽和を引き起こし、二次電流波形を歪め、変電所におけるリレーのアンダーリーチ、差動保護誤動作、過電流トリップの遅延、計測エラーにつながることを説明する技術インフォグラフィック。.](https://voltgrids.com/wp-content/uploads/2026/04/Residual-Magnetism-and-CT-Induction-Reliability-1024x619.jpg)\n\n残留磁気とCTインダクションの信頼性\n\n残留磁束は、すぐに目に見える故障を引き起こすわけではありません。これは隠れた劣化メカニズムであり、次の故障イベントで壊滅的な影響を受けるまで、保護システムの信頼性を静かに低下させます。この影響は、1つの主要なメカニズムによって生じます： **飽和前の磁束スイングが減少**.\n\nCTコアは飽和する前に有限の磁束密度の変化しかサポートできない。利用可能な磁束スイングの合計は\nΔB=Bサット−Br\\デルタB = B_{text{sat}}- B_{r}\n\n残留磁気のためにBrがすでにBsatの70%になっている場合、コアは次の故障電流過渡現象に利用できる通常の磁束容量の30%しか持っていません。これは、定格精度限界係数（ALF）が示唆するよりもはるかに早くCTが飽和し、保護リレーが正しく解釈できないひどく歪んだ二次電流波形を生成することを意味します。.\n\n**未対策の残留フラックスがもたらす現実的な影響：**\n\n- **距離リレーのアンダーリーチ：** CT出力が飽和すると [リレーの見かけのインピーダンスは、実際のインピーダ ンスよりも高い。](https://ieeexplore.ieee.org/document/4275376)[3](#fn-3), ゾーン内故障のトリップに失敗する可能性がある\n- **ディファレンシャル・プロテクションの誤操作：** 保護ゾーンの反対側にある CT 間の非対称な飽和は、誤った差動電流を発生させ、不要なトリップを引き起こす。\n- **過電流リレー遅延動作：** 歪んだ二次波形が、設計されたトリップカーブを超えてリレーの動作時間を延ばす\n- **エネルギー測定エラー：** 通常の負荷電流であっても、部分的に飽和したコアは、クラス0.5の制限を超える比率と位相角の誤差をもたらします。\n\n**顧客事例 - 電力会社、35kV変電所改修、中東：** サウジアラビアで35kV変電所の改修を管理する電力請負業者から、近くのバス故障に伴いフィーダー差動保護スキームで迷惑なトリップが繰り返されるとの報告がありました。Beptoの技術チームに相談したところ、CTの二次波形解析により、差動ゾーンの6つのCTのうち2つで高残留磁束と一致する深刻な非対称飽和が明らかになりました。6台すべてのユニットで構造的な消磁手順を実施した結果、差動保護の安定性が完全に回復し、リレー設定に起因すると誤認されていた3週間にわたる断続的な迷惑トリップが解消されました。."},{"heading":"変流器の磁界減磁方法は？","level":2,"content":"![あるフィールドエンジニアが、高圧開閉器の変流器（CT）二次コアの交流注入消磁を行っている。S1端子とS2端子に接続されたポータブル可変交流電源（Variac）を使用してゆっくりと電圧を下げながら、他の未使用コアを短絡している。この動作によってコア磁束はゼロ付近に収束し、磁区の矢印が集中する。.](https://voltgrids.com/wp-content/uploads/2026/04/Field-Demagnetization-via-AC-Injection-Method-1024x687.jpg)\n\n交流注入法による磁場消磁\n\n消磁の手順は次のようになる。 [徐々に小さくなるヒステリシス・ループを通してコアを駆動する](https://www.eaton.com/content/dam/eaton/products/medium-voltage-power-distribution-control-systems/switchgear/white-papers/ct-demagnetization-wp.pdf)[4](#fn-4) 残留磁束がほぼゼロに収束するまで。AC電圧注入と反転を伴うDC電流注入の2つの方法があり、それぞれ異なる現場条件やCT設計に適している。."},{"heading":"ステップ1：CT回路の分離と準備","level":3,"content":"- 一次側回路を非通電にし、電圧テスターで絶縁を確認する。\n- **未使用の CT 二次コアをすべて短絡する。** 開始する前に - いかなる残留磁束の状態でも、二次側端子が開回路になっていると危険な誘導電圧が発生する可能性があります。\n- 消磁される二次端子から保護リレーと計量負担を切り離す。\n- CT の銘板：定格比、精度クラス、ニーポイント電圧 (Vk)、および磁化電流 (Imag) を文書化する。"},{"heading":"ステップ2：消磁方法の選択","level":3,"content":"| 方法 | 必要な機材 | 最適 | 制限 |\n| AC電圧インジェクション（デガウジング） | 可変AC電源（バリアック）、電流計 | 標準5P/10P シリコン・スチール・コア | 可変電圧源へのアクセスが必要 |\n| リバーサル付き直流電流インジェクション | DC電源、反転スイッチ、電流計 | TPY/ギャップ付きコア、高インダクタンスCT | 慎重な電流反転シーケンスが必要 |\n| 専用CTアナライザー | 消磁機能内蔵CTアナライザー | すべてのコアタイプ - 最も信頼性が高い | 設備費用。 |"},{"heading":"ステップ3：ACインジェクション消磁手順（最も一般的なフィールド法）","level":3,"content":"1. 可変交流電圧源（Variac）を CT の二次側端子（S1-S2）に接続する。\n2. 着磁電流がほぼゼロになるまで、AC電圧をゼロからゆっくりと上昇させる。 **定格ニーポイント着磁電流の120-150%** - これによりコアが飽和状態になり、ヒステリシス・ループの開始点が確定する。\n3. **ゆっくりと連続的にAC電圧をゼロに戻す。** - 減速は30～60秒に渡り、スムーズかつ途切れることなく行わなければならない。\n4. コアフラックスは、徐々に小さなヒステリシスループを描き、電圧がゼロに近づくにつれて、ほぼゼロの残留磁束に収束する。\n5. 元の試験電圧で着磁電流を測定し、減磁前のベースラインと比較して磁束の減少を確認します。"},{"heading":"ステップ4：消磁の成功を確認する","level":3,"content":"- CTの実施 [励磁曲線](https://voltgrids.com/ja/blog/how-to-read-and-interpret-a-current-transformer-excitation-curve-for-instrument-transformer-health/) テスト（V-I特性）を行い、工場出荷時の着磁曲線と比較する。\n- 正常に消磁されたコアは、同じ印加電圧で工場出荷時のベースラインから±5%以内の着磁電流を示します。\n- 保護 CT の場合、ニーポイント電圧 (Vk) が銘板仕様に回復していることを確認する。\n- すべてのテスト結果を、以下の手順に従って変電所保守記録に記録する。 [IEC 61869-2 試運転要件](https://webstore.iec.ch/publication/5964)[5](#fn-5)"},{"heading":"ステップ5：二次回路の復元","level":3,"content":"1. 保護リレーと計量負担を正しい極性（S1→S2 方向）で再接続する。\n2. すべての負荷の接続が確認された後にのみ、二次短絡リンクを取り外すこと\n3. 一次側回路を再通電し、最初の負荷サイクル中にCT二次側出力を監視する。\n4. 保護リレー電流入力が、一次負荷電流および CT 比に基づく期待値と一致していることを確認する。"},{"heading":"中電圧 CT の減磁を失敗させる一般的な間違いとは？","level":2,"content":"![中電圧 CT の減磁失敗の原因を示す技術インフォグラフィック。これには、電圧降下の中断、過大な初期電圧、接続された 2 次側負担、励磁曲線の検証スキップ、多芯 CT の無視された磁気結合などが含まれ、信頼性の高い保護性能を実現するための処置後のチェックリストも掲載されています。.](https://voltgrids.com/wp-content/uploads/2026/04/Common-CT-Demagnetization-Mistakes-to-Avoid-1024x613.jpg)\n\n避けるべきCT消磁の一般的な誤り\n\n消磁は精密な手順であり、小さな実行ミスがコアに大きな残留磁束を残したり、最悪の場合、異なる極性で新たな残留磁束を発生させたりすることがあります。これらは、中電圧変電所の保守作業で観察される最も重大な現場ミスです。."},{"heading":"避けるべき重大なエラー","level":3,"content":"- **電圧降下を途中で止める：** ゼロでないレベルでAC電圧掃引を中断すると、コアは新しい残留磁化点でフリーズする。この減少は、ゼロまで連続的かつ途切れることなく続けなければならない。.\n- **過大な初期電圧の印加：** ニーポイント着磁電流の150%を超えてコアをオーバードライブすると、二次巻線に絶縁ストレスを与える危険があります。開始前に必ず安全な注入電圧限界を計算してください。.\n- **二次負担を接続した状態で消磁する：** 接続されたリレーインピーダンスは有効回路インダクタンスを変化させ、コアが完全なヒステリシスループを完了するのを妨げる。処置の前には必ず負担を切り離すこと。.\n- **励起曲線の検証をスキップする：** 目視検査では脱磁の成功を確認することはできません。工場出荷時のカーブに対する処置後のV-I特性テストのみが客観的な確認を提供します。.\n- **マルチコアユニットにおける隣接CTコアの無視：** デュアルコアCTでは、一方のコアを消磁すると、磁気カップリングによって隣接するコアの磁束変化を誘発する可能性があります。両方のコアを順次テストし、消磁する必要があります。."},{"heading":"手術後のチェックリスト","level":3,"content":"1. 励起曲線は工場のベースラインと±5%以内で一致する。\n2. ニーポイント電圧を銘板値に戻す\n3. 負担の再接続前に確認される二次極性マーク\n4. 負荷の再接続後、すべての短絡リンクを除去\n5. 整備記録に文書化された試験結果"},{"heading":"結論","level":2,"content":"変流器コアの残留磁束は、故障が日常的に発生し、保守チームが日常的に見過ごしている静かな信頼性の脅威です。消磁手順は、AC電圧スイープまたはDC電流反転のいずれによるものであっても、コアの利用可能な磁束振幅を完全に復元し、次の障害が発生したときに保護リレーが設計された精度限度内で動作するようにします。保護の信頼性が譲れない高圧配電システムにとって、消磁は是正措置ではなく、故障後の必須の試運転手順です。Bepto ElectricのCTはIEC 61869-2に準拠して製造されており、工場での励磁曲線を完全に文書化しているため、メンテナンスチームは毎回消磁の成功を確認するために必要なベースラインデータを得ることができます。."},{"heading":"CT消磁法に関するFAQ","level":2},{"heading":"**Q: 変流器のコアが故障後に著しい残留磁束を持つかどうかは、どのようにして分かりますか？**","level":3,"content":"**A:** 工場出荷時のベースラインに対して、故障後の励磁曲線（V-I特性）を比較する。同じ印加電圧で着磁電流が工場出荷時の値より著しく低い場合は、残留磁束が有効コア透磁率を低下させていることを示しており、減磁が必要です。."},{"heading":"**Q: CT コアに残留磁束があると、故障時に保護リレーがトリップしないことがありますか？**","level":3,"content":"**A:** はい。残留磁束は飽和前に利用可能な磁束スイングを減少させ、CT が定格 ALF よりも早く飽和する原因となります。結果として生じる歪んだ二次波形により、距離リレーが到達不足になり、過電流リレーが過度の時間遅延で動作する可能性があります。."},{"heading":"**Q: CT消磁は、高圧変電所ではどれくらいの頻度で行う必要がありますか？**","level":3,"content":"**A:** 消磁は、DC オフセット電流を伴う重大な故障事象の発生後、CT の二次側開回路事象の発生後、および CT の交換または保護スキームの変更後の定期試運転の一部として実行する必要があります。."},{"heading":"**Q: 残留磁束感受性に関して、TPYと5PクラスCTの違いは何ですか？**","level":3,"content":"**A:** TPYクラスCTはコアに小さなエアギャップを内蔵しており、残留磁束を10%以下に制限しているため、本質的に残留磁束が蓄積しにくくなっています。標準的な5PクラスのCTにはエアギャップがなく、故障後に60～80%のBsatが残留し、定期的な消磁が必要です。."},{"heading":"**Q: 隣のベイで一次バスがまだ通電している状態で CT の消磁を行っても安全ですか?**","level":3,"content":"**A:** CT の一次導体は、消磁の前に非通電および絶縁されなければならない。変電所の安全規則に従って適切な絶縁バリアが設置されていれば、隣接する通電ベイは許容されますが、試験装置を接続する前に、近くの導体からの誘導電圧を評価する必要があります。.\n\n1. “「変流器の残留磁束”、, `https://ieeexplore.ieee.org/document/7981358`. .保護変流器の残留磁気のIEEE解析。証拠の役割: メカニズム; 出典の種類: 研究.サポート：飽和磁束密度の60-80%。. [↩](#fnref-1_ref)\n2. “「IEC 61869-2:2012 計器変圧器-第 2 部”、, `https://webstore.iec.ch/publication/5964`. .ギャップ付きコア変流器の要件を定義している。エビデンスの役割：general_support; 出典の種類：標準。サポート：IEC 61869-2 による TPY および TPZ クラス。. [↩](#fnref-2_ref)\n3. “「CT飽和が距離保護に与える影響」、, `https://ieeexplore.ieee.org/document/4275376`. .歪んだ二次波形がどのようにリレーのアンダーリーチにつながるかを論じる。エビデンスの役割：メカニズム、出典の種類：研究。サポート：リレーは実際よりも高い見かけのインピーダンスを見る。. [↩](#fnref-3_ref)\n4. “「電流トランスのテストと消磁」、, `https://www.eaton.com/content/dam/eaton/products/medium-voltage-power-distribution-control-systems/switchgear/white-papers/ct-demagnetization-wp.pdf`. .イートンのテクニカルペーパーはフィールドAC注入手順を概説している。エビデンスの役割：メカニズム; 出典の種類：産業.サポート：徐々に小さくなるヒステリシスループを通してコアを駆動する。. [↩](#fnref-4_ref)\n5. “「IEC 61869-2:2012 計器変圧器”、, `https://webstore.iec.ch/publication/5964`. .計量器用変圧器の試運転及び試験基準を規定している。Evidence role: general_support; Source type: standard.サポート：IEC 61869-2 試運転要件。. [↩](#fnref-5_ref)"}],"source_links":[{"url":"https://voltgrids.com/ja/product-category/instrument-transformer/current-transformerct/","text":"カレント・トランス(CT)","host":"voltgrids.com","is_internal":true},{"url":"#what-is-residual-flux-and-why-does-it-form-in-ct-cores","text":"残留フラックスとは何か、なぜCTコアに形成されるのか？","is_internal":false},{"url":"#how-does-residual-magnetism-affect-ct-induction-performance-and-reliability","text":"残留磁気はCTインダクションの性能と信頼性にどのような影響を与えますか？","is_internal":false},{"url":"#how-do-you-perform-a-field-demagnetization-procedure-on-a-current-transformer","text":"変流器の磁界減磁方法は？","is_internal":false},{"url":"#what-are-common-mistakes-that-cause-demagnetization-to-fail-in-medium-voltage-cts","text":"中電圧 CT の減磁を失敗させる一般的な間違いとは？","is_internal":false},{"url":"https://voltgrids.com/ja/blog/understanding-ct-b-h-magnetization-curve/","text":"b-hヒステリシスループ","host":"voltgrids.com","is_internal":true},{"url":"https://ieeexplore.ieee.org/document/7981358","text":"飽和磁束密度60-80%","host":"ieeexplore.ieee.org","is_internal":false},{"url":"#fn-1","text":"1","is_internal":false},{"url":"https://webstore.iec.ch/publication/5964","text":"コア内の意図的なエアギャップ（IEC 61869-2によるTPYおよびTPZクラス）","host":"webstore.iec.ch","is_internal":false},{"url":"#fn-2","text":"2","is_internal":false},{"url":"https://ieeexplore.ieee.org/document/4275376","text":"リレーの見かけのインピーダンスは、実際のインピーダ ンスよりも高い。","host":"ieeexplore.ieee.org","is_internal":false},{"url":"#fn-3","text":"3","is_internal":false},{"url":"https://www.eaton.com/content/dam/eaton/products/medium-voltage-power-distribution-control-systems/switchgear/white-papers/ct-demagnetization-wp.pdf","text":"徐々に小さくなるヒステリシス・ループを通してコアを駆動する","host":"www.eaton.com","is_internal":false},{"url":"#fn-4","text":"4","is_internal":false},{"url":"https://voltgrids.com/ja/blog/how-to-read-and-interpret-a-current-transformer-excitation-curve-for-instrument-transformer-health/","text":"励磁曲線","host":"voltgrids.com","is_internal":true},{"url":"#fn-5","text":"5","is_internal":false},{"url":"#fnref-1_ref","text":"↩","is_internal":false},{"url":"#fnref-2_ref","text":"↩","is_internal":false},{"url":"#fnref-3_ref","text":"↩","is_internal":false},{"url":"#fnref-4_ref","text":"↩","is_internal":false},{"url":"#fnref-5_ref","text":"↩","is_internal":false}],"content_markdown":"![LDJ-10(Q)-210 現在の変圧器 10kV 屋内エポキシ樹脂- 5-1250A 複数の巻上げ 0.2S 0.5S 5P10 クラス 12 42 75kV 絶縁材のコンパクト デザイン GB1208 IEC60044-1](https://voltgrids.com/wp-content/uploads/2026/01/LDJ-10Q-210-Current-Transformer-10kV-Indoor-Epoxy-Resin-5-1250A-Multi-Winding-0.2S-0.5S-5P10-Class-12-42-75kV-Insulation-Compact-Design-GB1208-IEC60044-1.jpg)\n\n[カレント・トランス(CT)](https://voltgrids.com/ja/product-category/instrument-transformer/current-transformerct/)\n\n中電圧配電システムで故障が発生すると、ブレーカーが落ちるだけではなく、現在の変圧器コア内に目に見えないが危険な遺産が残る可能性がある： **残留磁気**. **故障またはDCオフセット過渡現象の後にCTコアに捕捉された残留磁束は、電磁誘導精度を直接劣化させ、コアの早期飽和を引き起こし、次の故障時に誤った保護リレー動作や危険なアンダーリーチを引き起こす可能性があります。.** 変電所の信頼性を担当する電気エンジニアや保守チームにとって、CT コアを正しく消磁する方法を知ることは、オプションの保守知識ではなく、最前線の保護システムの完全性タスクです。この記事では、残留磁束の物理学、段階的な現場消磁手順、および CT コアがそもそも残留磁束の影響を受けやすいかどうかを判断する選択基準について詳しく説明します。.\n\n## 目次\n\n- [残留フラックスとは何か、なぜCTコアに形成されるのか？](#what-is-residual-flux-and-why-does-it-form-in-ct-cores)\n- [残留磁気はCTインダクションの性能と信頼性にどのような影響を与えますか？](#how-does-residual-magnetism-affect-ct-induction-performance-and-reliability)\n- [変流器の磁界減磁方法は？](#how-do-you-perform-a-field-demagnetization-procedure-on-a-current-transformer)\n- [中電圧 CT の減磁を失敗させる一般的な間違いとは？](#what-are-common-mistakes-that-cause-demagnetization-to-fail-in-medium-voltage-cts)\n\n## 残留フラックスとは何か、なぜCTコアに形成されるのか？\n\n![粒方珪素鋼CTコアの詳細なクローズアップ図。この画像は、電流が除去された後、小さな磁区の矢印がほぼ一直線に並んだ内部結晶粒構造を示しており、コア内部に閉じ込められた高い残留磁束密度（Br）を視覚的に表している。このコアは、ケーブルや巻線が設置された大型の工業用電気パネルの一部であり、残留磁気の原因となった故障電流が発生したことを示している。.](https://voltgrids.com/wp-content/uploads/2026/04/CT-Core-with-Remaining-Residual-Flux-1024x687.jpg)\n\n残留フラックス付きCTコア\n\n残留磁束（残留磁気または残留磁束とも呼ばれる）とは、磁化力が除去された後にCTコアの粒方位珪素鋼構造の内部に閉じ込められたままの磁束密度のことである。なぜ残留磁束が形成されるのかを理解するには、以下の点を簡単に説明する必要があります。 [b-hヒステリシスループ](https://voltgrids.com/ja/blog/understanding-ct-b-h-magnetization-curve/) これはすべての強磁性コアの挙動を支配している。.\n\nCTが著しいDCオフセット成分を持つ故障電流を経験すると、一次電流はゼロ付近で対称的に振動しません。その代わりに、ヒステリシス曲線に沿って磁束密度の高い領域にコア磁束を駆動します。故障が解消され、電流が突然ゼロに低下した場合（サーキットブレーカーの遮断中に起こるような場合）、コアはゼロ磁束に戻りません。のままです。 **残留磁束密度（Br）**, に達することがある。 **[飽和磁束密度60-80%](https://ieeexplore.ieee.org/document/7981358)[1](#fn-1) (ビーサット)**.\n\nCTコア・リマネンスの主な技術的特徴：\n\n- **芯材の感度：** 高精度のCTに使用される）粒方珪素鋼は透磁率が高いが、残留磁化も高い。ニッケル-鉄合金コアはさらに高い残留磁化レベルを示す。.\n- **エアギャップ・コア：** で設計されたCTである。 [コア内の意図的なエアギャップ（IEC 61869-2によるTPYおよびTPZクラス）](https://webstore.iec.ch/publication/5964)[2](#fn-2) エアギャップが磁気リセット機構を提供するためである。.\n- **イベントを誘発する：** DCオフセット故障電流、CT二次側開回路事象、および試験後の不適切な消磁は、著しい残留磁束蓄積の3つの主な原因である。.\n\n| コア・タイプ | 残留レベル | IECクラス | 代表的なアプリケーション |\n| 粒状Si鋼（エアギャップなし） | 60-80% Bsat | 5P、10P、TPS | 標準保護CT |\n| ニッケル鉄合金（エアギャップなし） | 最大90% Bsat | クラスX、TPS | 高感度差動保護 |\n| ギャップドコア（小さなエアギャップ） |  | ティーピーワイ | オート・リクロース・プロテクション・スキーム |\n| 大型エアギャップ・コア | ~0% Bsat | ティーピーゼット | 高速保護、過渡性能 |\n\nスイッチギア・パネルに取り付けられているコアの種類によって、残留磁気のリスク・プロファイルが直接決定され、消磁手順が定期的に必須であるか、単なる予防措置であるかが決まります。.\n\n## 残留磁気はCTインダクションの性能と信頼性にどのような影響を与えますか？\n\n![残留磁気がCTの利用可能な磁束スイングを減少させ、コアの早期飽和を引き起こし、二次電流波形を歪め、変電所におけるリレーのアンダーリーチ、差動保護誤動作、過電流トリップの遅延、計測エラーにつながることを説明する技術インフォグラフィック。.](https://voltgrids.com/wp-content/uploads/2026/04/Residual-Magnetism-and-CT-Induction-Reliability-1024x619.jpg)\n\n残留磁気とCTインダクションの信頼性\n\n残留磁束は、すぐに目に見える故障を引き起こすわけではありません。これは隠れた劣化メカニズムであり、次の故障イベントで壊滅的な影響を受けるまで、保護システムの信頼性を静かに低下させます。この影響は、1つの主要なメカニズムによって生じます： **飽和前の磁束スイングが減少**.\n\nCTコアは飽和する前に有限の磁束密度の変化しかサポートできない。利用可能な磁束スイングの合計は\nΔB=Bサット−Br\\デルタB = B_{text{sat}}- B_{r}\n\n残留磁気のためにBrがすでにBsatの70%になっている場合、コアは次の故障電流過渡現象に利用できる通常の磁束容量の30%しか持っていません。これは、定格精度限界係数（ALF）が示唆するよりもはるかに早くCTが飽和し、保護リレーが正しく解釈できないひどく歪んだ二次電流波形を生成することを意味します。.\n\n**未対策の残留フラックスがもたらす現実的な影響：**\n\n- **距離リレーのアンダーリーチ：** CT出力が飽和すると [リレーの見かけのインピーダンスは、実際のインピーダ ンスよりも高い。](https://ieeexplore.ieee.org/document/4275376)[3](#fn-3), ゾーン内故障のトリップに失敗する可能性がある\n- **ディファレンシャル・プロテクションの誤操作：** 保護ゾーンの反対側にある CT 間の非対称な飽和は、誤った差動電流を発生させ、不要なトリップを引き起こす。\n- **過電流リレー遅延動作：** 歪んだ二次波形が、設計されたトリップカーブを超えてリレーの動作時間を延ばす\n- **エネルギー測定エラー：** 通常の負荷電流であっても、部分的に飽和したコアは、クラス0.5の制限を超える比率と位相角の誤差をもたらします。\n\n**顧客事例 - 電力会社、35kV変電所改修、中東：** サウジアラビアで35kV変電所の改修を管理する電力請負業者から、近くのバス故障に伴いフィーダー差動保護スキームで迷惑なトリップが繰り返されるとの報告がありました。Beptoの技術チームに相談したところ、CTの二次波形解析により、差動ゾーンの6つのCTのうち2つで高残留磁束と一致する深刻な非対称飽和が明らかになりました。6台すべてのユニットで構造的な消磁手順を実施した結果、差動保護の安定性が完全に回復し、リレー設定に起因すると誤認されていた3週間にわたる断続的な迷惑トリップが解消されました。.\n\n## 変流器の磁界減磁方法は？\n\n![あるフィールドエンジニアが、高圧開閉器の変流器（CT）二次コアの交流注入消磁を行っている。S1端子とS2端子に接続されたポータブル可変交流電源（Variac）を使用してゆっくりと電圧を下げながら、他の未使用コアを短絡している。この動作によってコア磁束はゼロ付近に収束し、磁区の矢印が集中する。.](https://voltgrids.com/wp-content/uploads/2026/04/Field-Demagnetization-via-AC-Injection-Method-1024x687.jpg)\n\n交流注入法による磁場消磁\n\n消磁の手順は次のようになる。 [徐々に小さくなるヒステリシス・ループを通してコアを駆動する](https://www.eaton.com/content/dam/eaton/products/medium-voltage-power-distribution-control-systems/switchgear/white-papers/ct-demagnetization-wp.pdf)[4](#fn-4) 残留磁束がほぼゼロに収束するまで。AC電圧注入と反転を伴うDC電流注入の2つの方法があり、それぞれ異なる現場条件やCT設計に適している。.\n\n### ステップ1：CT回路の分離と準備\n\n- 一次側回路を非通電にし、電圧テスターで絶縁を確認する。\n- **未使用の CT 二次コアをすべて短絡する。** 開始する前に - いかなる残留磁束の状態でも、二次側端子が開回路になっていると危険な誘導電圧が発生する可能性があります。\n- 消磁される二次端子から保護リレーと計量負担を切り離す。\n- CT の銘板：定格比、精度クラス、ニーポイント電圧 (Vk)、および磁化電流 (Imag) を文書化する。\n\n### ステップ2：消磁方法の選択\n\n| 方法 | 必要な機材 | 最適 | 制限 |\n| AC電圧インジェクション（デガウジング） | 可変AC電源（バリアック）、電流計 | 標準5P/10P シリコン・スチール・コア | 可変電圧源へのアクセスが必要 |\n| リバーサル付き直流電流インジェクション | DC電源、反転スイッチ、電流計 | TPY/ギャップ付きコア、高インダクタンスCT | 慎重な電流反転シーケンスが必要 |\n| 専用CTアナライザー | 消磁機能内蔵CTアナライザー | すべてのコアタイプ - 最も信頼性が高い | 設備費用。 |\n\n### ステップ3：ACインジェクション消磁手順（最も一般的なフィールド法）\n\n1. 可変交流電圧源（Variac）を CT の二次側端子（S1-S2）に接続する。\n2. 着磁電流がほぼゼロになるまで、AC電圧をゼロからゆっくりと上昇させる。 **定格ニーポイント着磁電流の120-150%** - これによりコアが飽和状態になり、ヒステリシス・ループの開始点が確定する。\n3. **ゆっくりと連続的にAC電圧をゼロに戻す。** - 減速は30～60秒に渡り、スムーズかつ途切れることなく行わなければならない。\n4. コアフラックスは、徐々に小さなヒステリシスループを描き、電圧がゼロに近づくにつれて、ほぼゼロの残留磁束に収束する。\n5. 元の試験電圧で着磁電流を測定し、減磁前のベースラインと比較して磁束の減少を確認します。\n\n### ステップ4：消磁の成功を確認する\n\n- CTの実施 [励磁曲線](https://voltgrids.com/ja/blog/how-to-read-and-interpret-a-current-transformer-excitation-curve-for-instrument-transformer-health/) テスト（V-I特性）を行い、工場出荷時の着磁曲線と比較する。\n- 正常に消磁されたコアは、同じ印加電圧で工場出荷時のベースラインから±5%以内の着磁電流を示します。\n- 保護 CT の場合、ニーポイント電圧 (Vk) が銘板仕様に回復していることを確認する。\n- すべてのテスト結果を、以下の手順に従って変電所保守記録に記録する。 [IEC 61869-2 試運転要件](https://webstore.iec.ch/publication/5964)[5](#fn-5)\n\n### ステップ5：二次回路の復元\n\n1. 保護リレーと計量負担を正しい極性（S1→S2 方向）で再接続する。\n2. すべての負荷の接続が確認された後にのみ、二次短絡リンクを取り外すこと\n3. 一次側回路を再通電し、最初の負荷サイクル中にCT二次側出力を監視する。\n4. 保護リレー電流入力が、一次負荷電流および CT 比に基づく期待値と一致していることを確認する。\n\n## 中電圧 CT の減磁を失敗させる一般的な間違いとは？\n\n![中電圧 CT の減磁失敗の原因を示す技術インフォグラフィック。これには、電圧降下の中断、過大な初期電圧、接続された 2 次側負担、励磁曲線の検証スキップ、多芯 CT の無視された磁気結合などが含まれ、信頼性の高い保護性能を実現するための処置後のチェックリストも掲載されています。.](https://voltgrids.com/wp-content/uploads/2026/04/Common-CT-Demagnetization-Mistakes-to-Avoid-1024x613.jpg)\n\n避けるべきCT消磁の一般的な誤り\n\n消磁は精密な手順であり、小さな実行ミスがコアに大きな残留磁束を残したり、最悪の場合、異なる極性で新たな残留磁束を発生させたりすることがあります。これらは、中電圧変電所の保守作業で観察される最も重大な現場ミスです。.\n\n### 避けるべき重大なエラー\n\n- **電圧降下を途中で止める：** ゼロでないレベルでAC電圧掃引を中断すると、コアは新しい残留磁化点でフリーズする。この減少は、ゼロまで連続的かつ途切れることなく続けなければならない。.\n- **過大な初期電圧の印加：** ニーポイント着磁電流の150%を超えてコアをオーバードライブすると、二次巻線に絶縁ストレスを与える危険があります。開始前に必ず安全な注入電圧限界を計算してください。.\n- **二次負担を接続した状態で消磁する：** 接続されたリレーインピーダンスは有効回路インダクタンスを変化させ、コアが完全なヒステリシスループを完了するのを妨げる。処置の前には必ず負担を切り離すこと。.\n- **励起曲線の検証をスキップする：** 目視検査では脱磁の成功を確認することはできません。工場出荷時のカーブに対する処置後のV-I特性テストのみが客観的な確認を提供します。.\n- **マルチコアユニットにおける隣接CTコアの無視：** デュアルコアCTでは、一方のコアを消磁すると、磁気カップリングによって隣接するコアの磁束変化を誘発する可能性があります。両方のコアを順次テストし、消磁する必要があります。.\n\n### 手術後のチェックリスト\n\n1. 励起曲線は工場のベースラインと±5%以内で一致する。\n2. ニーポイント電圧を銘板値に戻す\n3. 負担の再接続前に確認される二次極性マーク\n4. 負荷の再接続後、すべての短絡リンクを除去\n5. 整備記録に文書化された試験結果\n\n## 結論\n\n変流器コアの残留磁束は、故障が日常的に発生し、保守チームが日常的に見過ごしている静かな信頼性の脅威です。消磁手順は、AC電圧スイープまたはDC電流反転のいずれによるものであっても、コアの利用可能な磁束振幅を完全に復元し、次の障害が発生したときに保護リレーが設計された精度限度内で動作するようにします。保護の信頼性が譲れない高圧配電システムにとって、消磁は是正措置ではなく、故障後の必須の試運転手順です。Bepto ElectricのCTはIEC 61869-2に準拠して製造されており、工場での励磁曲線を完全に文書化しているため、メンテナンスチームは毎回消磁の成功を確認するために必要なベースラインデータを得ることができます。.\n\n## CT消磁法に関するFAQ\n\n### **Q: 変流器のコアが故障後に著しい残留磁束を持つかどうかは、どのようにして分かりますか？**\n\n**A:** 工場出荷時のベースラインに対して、故障後の励磁曲線（V-I特性）を比較する。同じ印加電圧で着磁電流が工場出荷時の値より著しく低い場合は、残留磁束が有効コア透磁率を低下させていることを示しており、減磁が必要です。.\n\n### **Q: CT コアに残留磁束があると、故障時に保護リレーがトリップしないことがありますか？**\n\n**A:** はい。残留磁束は飽和前に利用可能な磁束スイングを減少させ、CT が定格 ALF よりも早く飽和する原因となります。結果として生じる歪んだ二次波形により、距離リレーが到達不足になり、過電流リレーが過度の時間遅延で動作する可能性があります。.\n\n### **Q: CT消磁は、高圧変電所ではどれくらいの頻度で行う必要がありますか？**\n\n**A:** 消磁は、DC オフセット電流を伴う重大な故障事象の発生後、CT の二次側開回路事象の発生後、および CT の交換または保護スキームの変更後の定期試運転の一部として実行する必要があります。.\n\n### **Q: 残留磁束感受性に関して、TPYと5PクラスCTの違いは何ですか？**\n\n**A:** TPYクラスCTはコアに小さなエアギャップを内蔵しており、残留磁束を10%以下に制限しているため、本質的に残留磁束が蓄積しにくくなっています。標準的な5PクラスのCTにはエアギャップがなく、故障後に60～80%のBsatが残留し、定期的な消磁が必要です。.\n\n### **Q: 隣のベイで一次バスがまだ通電している状態で CT の消磁を行っても安全ですか?**\n\n**A:** CT の一次導体は、消磁の前に非通電および絶縁されなければならない。変電所の安全規則に従って適切な絶縁バリアが設置されていれば、隣接する通電ベイは許容されますが、試験装置を接続する前に、近くの導体からの誘導電圧を評価する必要があります。.\n\n1. “「変流器の残留磁束”、, `https://ieeexplore.ieee.org/document/7981358`. .保護変流器の残留磁気のIEEE解析。証拠の役割: メカニズム; 出典の種類: 研究.サポート：飽和磁束密度の60-80%。. [↩](#fnref-1_ref)\n2. “「IEC 61869-2:2012 計器変圧器-第 2 部”、, `https://webstore.iec.ch/publication/5964`. .ギャップ付きコア変流器の要件を定義している。エビデンスの役割：general_support; 出典の種類：標準。サポート：IEC 61869-2 による TPY および TPZ クラス。. [↩](#fnref-2_ref)\n3. “「CT飽和が距離保護に与える影響」、, `https://ieeexplore.ieee.org/document/4275376`. .歪んだ二次波形がどのようにリレーのアンダーリーチにつながるかを論じる。エビデンスの役割：メカニズム、出典の種類：研究。サポート：リレーは実際よりも高い見かけのインピーダンスを見る。. [↩](#fnref-3_ref)\n4. “「電流トランスのテストと消磁」、, `https://www.eaton.com/content/dam/eaton/products/medium-voltage-power-distribution-control-systems/switchgear/white-papers/ct-demagnetization-wp.pdf`. .イートンのテクニカルペーパーはフィールドAC注入手順を概説している。エビデンスの役割：メカニズム; 出典の種類：産業.サポート：徐々に小さくなるヒステリシスループを通してコアを駆動する。. [↩](#fnref-4_ref)\n5. “「IEC 61869-2:2012 計器変圧器”、, `https://webstore.iec.ch/publication/5964`. .計量器用変圧器の試運転及び試験基準を規定している。Evidence role: general_support; Source type: standard.サポート：IEC 61869-2 試運転要件。. [↩](#fnref-5_ref)","links":{"canonical":"https://voltgrids.com/ja/blog/how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event/","agent_json":"https://voltgrids.com/ja/blog/how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event/agent.json","agent_markdown":"https://voltgrids.com/ja/blog/how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event/agent.md"}},"ai_usage":{"preferred_source_url":"https://voltgrids.com/ja/blog/how-to-perform-a-demagnetization-procedure-for-current-transformers-after-a-fault-event/","preferred_citation_title":"故障後の変流器の減磁方法は？","support_status_note":"本パッケージは、公開されたWordPressの記事と抽出されたソースリンクを公開します。すべての主張を独自に検証するものではありません。."}}