LDBJ9-40.5 Current Transformer 40.5kV Indoor Epoxy Resin - 20-3000A 0.2S 0.5S 5P10 Class 150×In Thermal 375×In Dynamic 40.5 95 185kV GB1208 IEC60044-1

LDBJ9-40.5 Current Transformer 40.5kV Indoor Epoxy Resin – 20-3000A 0.2S/0.5S/5P10 Class 150×In Thermal 375×In Dynamic 40.5/95/185kV GB1208 IEC60044-1

JN22B-40.5-31.5 Indoor HV Earthing Switch 35-40.5kV 31.5kA - Electric Motor Operating 80kA Making YF-DJN-04 Controller KYN-40.5 Compatible CE Certified

JN22B-40.5/31.5 Indoor HV Earthing Switch 35-40.5kV 31.5kA – Electric Motor Operating 80kA Making YF-DJN-04 Controller KYN-40.5 Compatible CE Certified

JN22-40.5-31.5 Indoor HV Earthing Switch 35-40.5kV 31.5kA - 80kA Making Current 95kV Power Frequency 185kV Lightning Impulse KYN Switchgear Compatible

JN22-40.5/31.5 Indoor HV Earthing Switch 35-40.5kV 31.5kA – 80kA Making Current 95kV Power Frequency 185kV Lightning Impulse KYN Switchgear Compatible

JN15-12 Indoor HV Earthing Switch 12kV 630A 31.5kA - Switchgear Grounding Protection 42kV Power Frequency 75kV Lightning Impulse 80kA Making Current

JN15 Indoor AC HV Earthing Switch 12-40.5kV 31.5kA – Short-Circuit Making Capacity 80kA 65kV Power Frequency 125kV Lightning Impulse Resin Insulator

GW13 Outdoor Neutral Disconnecting Switch 40.5-126kV 630A - 50° Pillar Insulator Intersection 25° Tilted Bracket CS17G Manual CJ6 Electric Mechanism

GW13 Outdoor Neutral Disconnecting Switch 40.5-126kV 630A – 50° Pillar Insulator Intersection 25° Tilted Bracket CS17G Manual CJ6 Electric Mechanism

GW5 Outdoor AC HV Disconnector 40.5-126kV 630-2000A - Pillar Insulator Level 0II Anti-Pollution Type -30°C to +40°C 2000m

GW5 Outdoor AC HV Disconnector 40.5-126kV 630-2000A – Pillar Insulator Level 0/II Anti-Pollution Type -30°C to +40°C 2000m Altitude 34m/s Wind

GW1 Outdoor AC HV Disconnect Switch 12-40.5kV 630-1250A - Three-Pole Linkage IEC62271-103 Anti-Pollution Type 5060Hz 20-25kA 2000 Life

GW1 Outdoor AC HV Disconnect Switch 12-40.5kV 630-1250A – Three-Pole Linkage IEC62271-103 Anti-Pollution Type 50/60Hz 20-25kA 2000 Life

GW4 Outdoor HV Disconnector 12-40.5kV 200-1250A - Fixed Draw Hook Self-Locking Insulating Hook-Stick Anti-Pollution Type Class IV 16-31.5kA

GW4 Outdoor HV Disconnector 12-40.5kV 200-1250A – Fixed Draw Hook Self-Locking Insulating Hook-Stick Anti-Pollution Type Class IV 16-31.5kA

GN27-40.5 Indoor HV Isolating Switch 40kV 630-1250A - Vertical Rotating Blade CS6-2 Manual CX6 Electric 10-110kV Power System No-Load Circuit

GN27-40.5 Indoor HV Isolating Switch 40kV 630-1250A – Vertical Rotating Blade CS6-2 Manual CX6 Electric 10-110kV Power System No-Load Circuit

ZW39-40.5 Outdoor High Voltage Vacuum Circuit Breaker 35kV - CT10-A Spring Mechanism Frequent Operation Contact Breaker GB1984 IEC Compliant