Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.
EK6-12/31.5 Indoor AC HV Combined Earthing Switch 12kV 630-2000A: Smart grounding switch, 31.5kA short-time withstand, 80kA making current, 42kV power frequency, 75kV lightning impulse, resin insulator, silver-plated copper 99.9%, 4s withstand time, 2000 times life, ISO certified, GB1985 IEC129 compliant.
Advanced EK6-12/31.5 Indoor AC High Voltage Combined Earthing Switch: Advanced level product with high-tech parameters performance and smart technology conforming to GB1985 and IEC129 standards, applies to power system 3-12kV and three-phase AC 50Hz, owns short-circuit making capacity to protect other electric equipment from damage, rated voltage 12kV with wide current range 630-2000A, rated short-time withstand current 31.5kA for 4 seconds, rated short-circuit making current 80kA with rated peak withstand current 80kA, rated insulation level with power frequency withstand voltage 42kV (phase to earth/phase to phase, 1 min) and lightning impulse withstand voltage 75kV, mechanical endurance 2000 times, ISO certified.
Superior Smart Grounding Switch with Resin Insulator Construction: EK6-12/31.5 uses resin insulators with live parts made of silver-plated electrolytic copper (99.9%), blades directly connected to drive shaft, contact elements overdimensioned with high contact pressure ensuring reduced ohmic resistance and minimum metal wear-off with robustness to withstand thermal and mechanical stresses under short-circuit conditions, smart technology for intelligent operation, wide current range 630-2000A meeting diverse application requirements, ambient conditions: altitude <1000m, temperature -10°C to +40°C, earthquake intensity ≤8 degrees, pollution degree II, relative humidity daily average <95% monthly average <90%, can be used with various high voltage switchgear playing protective role in high-voltage electrical equipment overhaul.
| Specification Unit: (mm) |
E | F | G | H | D | C |
| EK6-12/31.5-165 | 165 | 75 | 160 | 565 | 426 | |
| EK6-12/31.5-180 | 180 | 75 | 160 | 595 | 456 | |
| EK6-12/31.5-200 | 200 | 75 | 160 | 635 | 496 | |
| EK6-12/31.5-210 | 210 | 75 | 160 | 655 | 516 | |
| EK6-12/31.5-220 | 220 | 75 | 160 | 675 | 536 | |
| EK6-12/31.5-230 | 230 | 75 | 160 | 695 | 556 | 96 |
| EK6-12/31.5-250 | 250 | 75 | 160 | 735 | 596 | 96 |
| EK6-12/31.5-275 | 275 | 75 | 185 | 810 | 646 | 96 |
| EK6-12/31.5 Indoor AC HV Combined Earthing Switch Specifications | Parameter | Unit |
|---|---|---|
| Brand | Bepto Insulation Systems | – |
| Model Number | EK6-12/31.5 | – |
| Category | Switchgear & High Voltage Combined Earthing Switch | – |
| Product Type | Indoor AC HV Combined Earthing Switch (12kV 630-2000A 31.5kA) Smart Grounding Switch with 80kA Making Current, 42kV Power Frequency, 75kV Lightning Impulse, ISO Certified | – |
| Core Technology | Advanced Level Product with High-Tech Parameters Performance + Smart Technology + ISO Certification + GB1985 and IEC129 Standards Compliant + 3-12kV Power System Application + Three-Phase AC 50Hz + Short-Circuit Making Capacity to Protect Electric Equipment + Rated Voltage 12kV + Wide Current Range 630-2000A + Rated Short-Time Withstand Current 31.5kA + Rated Short-Circuit Duration 4 Seconds + Rated Short-Circuit Making Current 80kA + Rated Peak Withstand Current 80kA + Power Frequency Withstand Voltage 42kV (Phase to Earth/Phase to Phase, 1 Min) + Lightning Impulse Withstand Voltage 75kV + Mechanical Endurance 2000 Times + Resin Insulators + Silver-Plated Electrolytic Copper (99.9%) Live Parts + Blades Directly Connected to Drive Shaft + Overdimensioned Contact Elements + High Contact Pressure + Reduced Ohmic Resistance + Minimum Metal Wear-Off + Robustness to Withstand Thermal and Mechanical Stresses Under Short-Circuit Conditions + Combined Power Supply Application + Various High Voltage Switchgear Compatibility + Equipment Overhaul Protection | – |
| Certification | ISO | – |
| Whether Smart | Yes | – |
| Place of Origin | Zhejiang, China | – |
| Product Name | Grounding Switch EK6-12/31.5 | – |
| Rated Voltage | 12 | kV |
| Max. Voltage | 12 | kV |
| Rated Current Range | 630-2000 | A |
| Max. Current | 2000 | A |
| Rated Frequency | 50 | Hz |
| Rated Short-Time Withstand Current | 31.5 | kA |
| Rated Short-Circuit Duration | 4 | s |
| Rated Short-Circuit Making Current | 80 | kA |
| Rated Peak Withstand Current | 80 | kA |
| Power Frequency Withstand Voltage (1 Min) – Phase to Earth | 42 | kV |
| Power Frequency Withstand Voltage (1 Min) – Phase to Phase | 42 | kV |
| Lightning Impulse Withstand Voltage | 75 | kV |
| Mechanical Endurance (Mechanism Life) | 2000 | Times |
| Installation Type | Indoor | – |
| Current Type | AC (Alternating Current) | – |
| Phase | Three-Phase | – |
| Voltage Range Application | 3-12kV | kV |
| Application Type | Combined Earthing Switch, Power Supply Grounding Switch | – |
| Standards Compliance | GB1985 and IEC129 | – |
| ISO Certified | Yes (ISO Certification) | – |
| Smart Technology | Yes (Smart Grounding Switch) | – |
| Advanced Level Product | Yes (Advanced Level Product with High-Tech Parameters Performance) | – |
| GB1985 Compliant | Yes (Conforms to GB1985 Standard) | – |
| IEC129 Compliant | Yes (Conforms to IEC129 Standard) | – |
| 3-12kV Power System | Yes (Applies to Power System 3-12kV) | – |
| Three-Phase AC 50Hz | Yes (Three-Phase AC 50Hz) | – |
| Short-Circuit Making Capacity | Yes (Owns Short-Circuit Making Capacity to Protect Other Electric Equipment from Damage) | – |
| Wide Current Range 630-2000A | Yes (Rated Current 630-2000A) | – |
| 31.5kA Short-Time Withstand | Yes (Rated Short-Time Withstand Current 31.5kA) | – |
| 4 Seconds Duration | Yes (Rated Short-Circuit Duration 4 Seconds) | – |
| 80kA Making Current | Yes (Rated Short-Circuit Making Current 80kA) | – |
| 80kA Peak Withstand | Yes (Rated Peak Withstand Current 80kA) | – |
| 42kV Power Frequency | Yes (Power Frequency Withstand Voltage 42kV Phase to Earth/Phase to Phase, 1 Min) | – |
| 75kV Lightning Impulse | Yes (Lightning Impulse Withstand Voltage 75kV) | – |
| 2000 Times Life | Yes (Mechanical Endurance 2000 Times) | – |
| Resin Insulators | Yes (Grounding Switches Use Resin Insulators) | – |
| Silver-Plated Electrolytic Copper (99.9%) | Yes (Live Parts Made of Silver-Plated Electrolytic Copper 99.9%) | – |
| Blades Connected to Drive Shaft | Yes (Blades Directly Connected to Drive Shaft) | – |
| Overdimensioned Contact Elements | Yes (Contact Elements Overdimensioned According to Requirements) | – |
| High Contact Pressure | Yes (High Contact Pressure Between Blades and Contacts) | – |
| Reduced Ohmic Resistance | Yes (Reduced Ohmic Resistance at Contact Surface) | – |
| Minimum Metal Wear-Off | Yes (Minimum Metal Wear-Off During Life of Grounding Switch) | – |
| Thermal Mechanical Stresses Robustness | Yes (Robustness to Withstand Thermal and Mechanical Stresses Under Short-Circuit Conditions) | – |
| Combined Power Supply Application | Yes (Indoor AC High Voltage Power Supply Combined Earthing Switch) | – |
| Various HV Switchgear Compatibility | Yes (Can Be Used with Various High Voltage Switchgear) | – |
| Equipment Overhaul Protection | Yes (Play Protective Role in High-Voltage Electrical Equipment Overhaul) | – |
| No. | Ambient Condition | Parameter |
|---|---|---|
| 1 | Altitude | Less Than 1000m |
| 2 | Ambient Temperature | -10°C to +40°C |
| 3 | Earthquake Intensity | No More Than 8 Degrees |
| 4 | Pollution | II |
| 5 | Relative Humidity | Daily Average Less Than 95%, Monthly Average Less Than 90% |
| Item | Unit | Data |
|---|---|---|
| Rated Voltage | kV | 12 |
| Rated Short-Time Withstand Current | kA | 31.5 |
| Rated Short-Circuit Duration | s | 4 |
| Rated Short-Circuit Making Current | kA | 80 |
| Rated Peak Withstand Current | kA | 80 |
| Rated Insulation Level – PF Withstand Voltage (1 Min) Phase to Earth | kV | 42 |
| Rated Insulation Level – PF Withstand Voltage (1 Min) Phase to Phase | kV | 42 |
| Rated Insulation Level – Lightning Impulse Withstand Voltage | kV | 75 |
| Mechanical Endurance (Mechanism Life) | Times | 2000 |
| Rated Current Options | Value |
|---|---|
| Minimum Current | 630A |
| Maximum Current | 2000A |
| Current Range | 630A – 2000A |
Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.
Bepto focuses on the global market and provides our clients with products suitable for the local market:
Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.