Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.
IACM Manually Operated Overhead Switch: 36kV 400A air-break disconnector, isolate/restore line sections, maintenance/troubleshooting, human intervention, 2000m altitude, IEC compliant, -30°C to +40°C.
Advanced IACM Manually Operated Overhead Switch Series: Premium IACM-12~36/400-50A overhead switch physically operated by personnel to isolate or restore line sections for maintenance and troubleshooting operations requiring human intervention, featuring air-break technology with isolation gate knife and arc rod for rapid energy storage movement, arc lengthening and air cooling extinguishment independent of manual operation speed, delivering 200-1250A rated current with 50A active load breaking, 2.5A no-load transformer breaking, 10A no-load line breaking capacity, 12.5kA (1s) short-time withstand, 31.5kA peak withstand, 2000 mechanical cycles, compliant with IEC60265-1, IEC62271-1, IEC62271-103 standards.
Maintenance and Troubleshooting Ready: IACM incorporates simple structure, less maintenance, strong arc extinguishing ability, high insulation level break, high reliability for radial/ring network lines, transformer circuits with HV current limiting fuses or current-free isolation, operating at -30°C to +40°C, altitudes ≤2000m, Grade IV air pollution, earthquake intensity ≤8, providing reliable manually operated air-break overhead switching solution for line section isolation, restoration, maintenance and troubleshooting operations requiring human intervention.
| IACM Manually Operated Overhead Switch Specifications | 12kV | 17.5kV | 24kV | 36kV | Unit |
|---|---|---|---|---|---|
| Model Number | IACM-12/400-50A | IACM-17.5/400-50A | IACM-24/400-50A | IACM-36/400-50A | – |
| Alternative Model | ISAR-S-12 | ISAR-S-17.5 | ISAR-S-24 | ISAR-S-36 | – |
| Brand | Bepto Insulation Systems | Bepto Insulation Systems | Bepto Insulation Systems | Bepto Insulation Systems | – |
| Product Type | Manually Operated Overhead Switch (Air-Break Load-Break Disconnector) | Manually Operated Overhead Switch (Air-Break Load-Break Disconnector) | Manually Operated Overhead Switch (Air-Break Load-Break Disconnector) | Manually Operated Overhead Switch (Air-Break Load-Break Disconnector) | – |
| Operation Method | Physically Operated by Personnel (Human Intervention) | Physically Operated by Personnel (Human Intervention) | Physically Operated by Personnel (Human Intervention) | Physically Operated by Personnel (Human Intervention) | – |
| Primary Function | Isolate or Restore Line Sections | Isolate or Restore Line Sections | Isolate or Restore Line Sections | Isolate or Restore Line Sections | – |
| Application Focus | Maintenance and Troubleshooting Operations | Maintenance and Troubleshooting Operations | Maintenance and Troubleshooting Operations | Maintenance and Troubleshooting Operations | – |
| Rated Voltage | 12 | 17.5 | 24 | 36 | kV |
| Rated Current | 200/400/630/1250 | 200/400/630/1250 | 200/400/630/1250 | 200/400/630/1250 | A |
| Rated Active Load Breaking Current | 50 | 50 | 50 | 50 | A |
| Rated No-Load Transformer Breaking | 2.5 | 2.5 | 2.5 | 2.5 | A |
| Rated No-Load Line Breaking Capacity | 10 | 10 | 10 | 10 | A |
| 1min Power Frequency Withstand (Phase/Earth) | 42 | 45 | 55 | 95 | kV |
| Power Frequency Withstand (Open Contacts) | 48 | 55 | 69 | 105 | kV |
| Lightning Impulse Withstand (Phase/Earth) | 75 | 95 | 125 | 170 | kV |
| Lightning Impulse Withstand (Open Contacts) | 85 | 105 | 145 | 195 | kV |
| Rated Short-Time Withstand Current | 12.5 | 12.5 | 12.5 | 12.5 | kA |
| Rated Short-Circuit Duration | 1 | 1 | 1 | 1 | s |
| Rated Peak Withstand Current | 31.5 | 31.5 | 31.5 | 31.5 | kA |
| Mechanical Life | 2000 | 2000 | 2000 | 2000 | cycles |
| Manual Operating Torque | ≤200 | ≤200 | ≤200 | ≤200 | Nm |
| Contact Opening Distance | >500 | >600 | >800 | >1030 | mm |
| Contact Pressure | 200 | 200 | 200 | 200 | N |
| Main Loop Resistance | ≤150 | ≤150 | ≤150 | ≤150 | μΩ |
| Arc Extinguishing Technology | Air-Break (Isolation Gate Knife + Arc Rod) | Air-Break (Isolation Gate Knife + Arc Rod) | Air-Break (Isolation Gate Knife + Arc Rod) | Air-Break (Isolation Gate Knife + Arc Rod) | – |
| Arc Rod Function | Rapid Energy Storage Movement, Arc Lengthening, Air Cooling Extinguishment | Rapid Energy Storage Movement, Arc Lengthening, Air Cooling Extinguishment | Rapid Energy Storage Movement, Arc Lengthening, Air Cooling Extinguishment | Rapid Energy Storage Movement, Arc Lengthening, Air Cooling Extinguishment | – |
| Arc Movement Speed | Independent of Manual Operation Speed | Independent of Manual Operation Speed | Independent of Manual Operation Speed | Independent of Manual Operation Speed | – |
| Ambient Temperature | -30 to +40 | -30 to +40 | -30 to +40 | -30 to +40 | °C |
| Daily Temperature Difference | ≤32 | ≤32 | ≤32 | ≤32 | K |
| Altitude | ≤2000 | ≤2000 | ≤2000 | ≤2000 | m |
| Air Pollution Level | Grade IV (GB5585) | Grade IV (GB5585) | Grade IV (GB5585) | Grade IV (GB5585) | – |
| Max Wind Pressure | ≤700 | ≤700 | ≤700 | ≤700 | MPa |
| Earthquake Intensity | ≤8 | ≤8 | ≤8 | ≤8 | – |
| Ice Thickness | ≤10 | ≤10 | ≤10 | ≤10 | mm |
| Standards Compliance | IEC60265-1, IEC62271-1, IEC62271-103 | IEC60265-1, IEC62271-1, IEC62271-103 | IEC60265-1, IEC62271-1, IEC62271-103 | IEC60265-1, IEC62271-1, IEC62271-103 | – |
| Application | Overhead Power Lines, Line Section Isolation/Restoration, Maintenance Operations, Troubleshooting Operations, Radial/Ring Network Lines, Transformer Circuits with HV Fuses, Current-Free Isolation | Overhead Power Lines, Line Section Isolation/Restoration, Maintenance Operations, Troubleshooting Operations, Radial/Ring Network Lines, Transformer Circuits with HV Fuses, Current-Free Isolation | Overhead Power Lines, Line Section Isolation/Restoration, Maintenance Operations, Troubleshooting Operations, Radial/Ring Network Lines, Transformer Circuits with HV Fuses, Current-Free Isolation | Overhead Power Lines, Line Section Isolation/Restoration, Maintenance Operations, Troubleshooting Operations, Radial/Ring Network Lines, Transformer Circuits with HV Fuses, Current-Free Isolation | – |
Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.
Bepto focuses on the global market and provides our clients with products suitable for the local market:
Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.