JDZ(X)9-3/6/10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3/6P Class Phase-to-Ground Dual Secondary 12/42/75kV Insulation 500-600VA Max Output GB1207 IEC60044-2

Description:

JDZ(X)9-3/6/10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, phase-to-phase and phase-to-ground measurement, 3kV/√3-10kV/√3/100V/√3+100V/3 ratio, 0.2/0.5/1/3/6P accuracy class, dual secondary winding option, epoxy resin casting insulation, 3.6-12/25-42/40-75kV insulation level, 30-500VA burden, 500-600VA max output, 50-60Hz, GB1207 IEC60044-2.

Applications:

Advanced JDZ(X)9 High-Capacity Epoxy Resin Casting Transformer Series: Indoor single-phase epoxy resin casting voltage transformer conforming to GB1207 and IEC60044-2 standards, six voltage configurations available (JDZ9-3Q/6Q/10Q for phase-to-phase, JDZX9-3G/6G/10G for phase-to-ground), rated insulation levels 3.6/25/40kV, 7.2/32/60kV, and 12/42/75kV respectively, rated frequency 50Hz or 60Hz, designed for voltage and electric energy measurement and relay protection in indoor switchgear and distribution systems, innovative epoxy resin casting insulation providing superior moisture resistance, environmental protection, and maintenance-free operation, high output capacity 500-600VA enabling connection of multiple loads, JDZ9 series for phase-to-phase voltage measurement (3kV/100V, 6kV/100V, 10kV/100V), JDZX9 series for phase-to-ground measurement with protection winding (3kV/√3/100V/√3+100V/3, 6kV/√3/100V/√3+100V/3, 10kV/√3/100V/√3+100V/3), dual secondary winding configurations available for simultaneous metering applications, accuracy classes 0.2/0.5/1/3/6P with burden capacity 30-500VA.

Superior Epoxy Resin Casting Technology and Phase-to-Ground Measurement Capability: JDZ(X)9 series features advanced epoxy resin casting insulation ensuring excellent moisture resistance, environmental protection, flame retardancy, and maintenance-free operation with no oil leakage concerns, exceptional 500-600VA maximum output capacity providing ability to connect multiple metering devices, instruments, and protection relays simultaneously, compact design ideal for indoor switchgear installations, three voltage levels (3kV/6kV/10kV) offering flexibility for various distribution voltage applications, JDZX9 series with dedicated 100V/3 protection winding for relay protection applications (6P class), dual secondary winding option enabling dual metering applications with 0.2/0.2, 0.2/0.5, or 0.5/0.5 accuracy combinations, suitable for indoor switchgear, distribution substations, industrial facilities, commercial buildings, and applications requiring high output capacity voltage measurement from 3kV to 10kV with epoxy resin casting reliability and phase-to-ground measurement capability.

Specifications

JDZ(X)9-3 6 10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 6P Class Phase-to-Ground Dual Secondary 12 42 75kV Insulation 500-600VA Max Output

Wiring Diagram Model Type Configuration Application
Figure 1–2 JDZ9-3Q/6Q/10Q Single secondary winding for phase-to-phase measurement Phase-to-phase voltage measurement
Figure 3–4 JDZ9-10Q (Dual) Dual secondary windings (100V + 100V) Dual metering applications
Figure 5 JDZX9-3G/6G/10G Dual secondary windings (100V/√3 + 100V/3) Phase-to-ground measurement + protection
Figure 6 JDZX9-10G (Triple) Triple secondary windings (100V/√3 + 100V/√3 + 100V/3) Dual metering + protection

JDZ(X)9-3 6 10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 6P Class Phase-to-Ground Dual Secondary 12 42 75kV Insulation 500-600VA Max Output

 

Features

JDZ(X)9-3/6/10Q(G) Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JDZ(X)9-3/6/10Q(G) Series (JDZ9-3Q/6Q/10Q, JDZX9-3G/6G/10G)
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 3kV/6kV/10kV Indoor Single-Phase Epoxy Resin Casting Voltage Transformer with Phase-to-Phase and Phase-to-Ground Measurement, Dual Secondary Winding, 0.2/0.5/1/3/6P Accuracy Class, 3.6-12/25-42/40-75kV Insulation, 500-600VA High Output Capacity for Voltage & Energy Measurement and Relay Protection
Core Technology Indoor Single-Phase Epoxy Resin Casting Design + Multi-Voltage Flexibility (3kV/6kV/10kV) + Phase-to-Phase and Phase-to-Ground Measurement Capability + Dual Secondary Winding Configuration + High Output Capacity (500-600VA) + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Levels (3.6/25/40kV, 7.2/32/60kV, 12/42/75kV) + Rated Frequency 50Hz or 60Hz + Voltage Ratios (Phase-to-Phase and Phase-to-Ground Options) + Accuracy Classes (0.2, 0.5, 1, 3, 6P) + Burden Capacity 30-500VA + Maximum Output 500-600VA + Superior Moisture Resistance + Environmental Protection + Flame Retardancy + Maintenance-Free Operation + No Oil Leakage + Compact Design + Proven Epoxy Resin Technology
Power (Voltage) 3kV / 6kV / 10kV
Rated Voltage (JDZ9-3Q) 3 kV
Rated Voltage (JDZ9-6Q) 6 kV
Rated Voltage (JDZ9-10Q) 10 kV
Rated Voltage (JDZX9-3G) 3/√3 (1.73) kV
Rated Voltage (JDZX9-6G) 6/√3 (3.46) kV
Rated Voltage (JDZX9-10G) 10/√3 (5.77) kV
Voltage Ratio (JDZ9-3Q) 3000/100 V
Voltage Ratio (JDZ9-6Q) 6000/100 V
Voltage Ratio (JDZ9-10Q) 10000/100 V
Voltage Ratio (JDZX9-3G) 3000/√3/100/√3 + 100/3 (1732/57.7 + 33.3) V
Voltage Ratio (JDZX9-6G) 6000/√3/100/√3 + 100/3 (3464/57.7 + 33.3) V
Voltage Ratio (JDZX9-10G) 10000/√3/100/√3 + 100/3 (5774/57.7 + 33.3) V
Voltage Ratio (JDZ9-10Q Dual) 10000/100 + 100 V
Voltage Ratio (JDZX9-10G Triple) 10000/√3/100/√3 + 100/√3 + 100/3 V
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 3, 6P
Insulation Level (JDZ9-3Q/JDZX9-3G) 3.6/25/40 kV
Insulation Level (JDZ9-6Q/JDZX9-6G) 7.2/32/60 kV
Insulation Level (JDZ9-10Q/JDZX9-10G) 12/42/75 kV
Max Output (JDZ9-3Q) 500 VA
Max Output (JDZ9-6Q) 500 VA
Max Output (JDZ9-10Q) 500 VA
Max Output (JDZ9-10Q Dual) 400/400 VA
Max Output (JDZX9-6G) 600 VA
Max Output (JDZX9-10G) 600 VA
Max Output (JDZX9-10G Triple) 400/400 VA
Burden Capacity (0.2 Class) 30-40 VA
Burden Capacity (0.5 Class) 60-100 VA
Burden Capacity (1 Class) 180-200 VA
Burden Capacity (3 Class) 240-500 VA
Burden Capacity (6P Class) 100 VA
Burden Capacity (0.2/0.2 Dual) 15/15-20/20 VA
Burden Capacity (0.2/0.5 Dual) 15/20-20/30 VA
Burden Capacity (0.5/0.5 Dual) 30/30-40/40 VA
Insulation Type Epoxy Resin Casting
Structure Type Indoor Single-Phase Epoxy Resin Casting
Voltage Level Low-Medium Voltage (3kV/6kV/10kV)
Installation Type Indoor
Phase Single Phase
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Multi-Voltage 3kV/6kV/10kV Yes (Three Voltage Levels Available)
Epoxy Resin Casting Yes (Epoxy Resin Casting Insulation)
Single-Phase Yes (Single-Phase Configuration)
Indoor Construction Yes (Indoor Installation)
500-600VA High Output Yes (500-600VA Maximum Output Capacity)
Phase-to-Phase Measurement Yes (JDZ9 Series)
Phase-to-Ground Measurement Yes (JDZX9 Series)
Dual Secondary Winding Yes (Dual Secondary Available)
Triple Secondary Winding Yes (Triple Secondary Available for JDZX9-10G)
Protection Winding (100V/3) Yes (JDZX9 Series with 6P Class)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
3.6-12/25-42/40-75kV Insulation Yes (Rated Insulation Levels)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
3 Accuracy Class Yes (3 Monitoring Accuracy Class Available)
6P Protection Class Yes (6P Protection Accuracy Class Available)
VKV Compatible Yes (JDZ9 Series Same as VKV)
Moisture Resistance Yes (Superior Moisture Resistance)
Environmental Protection Yes (Environmentally Friendly)
Flame Retardancy Yes (Flame Retardant Properties)
Maintenance-Free Yes (No Maintenance Required)
No Oil Leakage Yes (Solid Insulation, No Oil)
Compact Design Yes (Compact for Indoor Switchgear)
JDZ9 Series (Line-to-Line Voltage Measurement)
Model Type Rated Voltage Voltage Ratio Insulation Level Max Output Application
JDZ9-3Q 3kV 3000/100V 3.6/25/40kV 500VA 3kV phase-to-phase measurement with high output
JDZ9-6Q 6kV 6000/100V 7.2/32/60kV 500VA 6kV phase-to-phase measurement with high output
JDZ9-10Q 10kV 10000/100V 12/42/75kV 500VA 10kV phase-to-phase measurement with high output
JDZ9-10Q (Dual) 10kV 10000/100 + 100V 12/42/75kV 400/400VA 10kV dual metering applications
JDZX9 Series (Phase-to-Earth Voltage Measurement and Protection)
Model Type Rated Voltage Voltage Ratio Insulation Level Max Output Application
JDZX9-3G 3kV/√3 (1.73kV) 3kV/√3/100V/√3 + 100V/3 3.6/25/40kV 3kV phase-to-ground measurement + protection
JDZX9-6G 6kV/√3 (3.46kV) 6kV/√3/100V/√3 + 100V/3 7.2/32/60kV 600VA 6kV phase-to-ground measurement + protection
JDZX9-10G 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/3 12/42/75kV 600VA 10kV phase-to-ground measurement + protection
JDZX9-10G (Triple) 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/√3 + 100V/3 12/42/75kV 400/400VA 10kV dual metering + protection
500-600VA High Output Capacity Feature Description Benefit
High Power Rating 500-600VA maximum output capacity Supports connection of multiple metering devices and instruments simultaneously
JDZ9 Series 500VA 500VA output for phase-to-phase measurement Adequate capacity for multiple loads in phase-to-phase applications
JDZX9 Series 600VA 600VA output for phase-to-ground measurement Higher capacity for phase-to-ground measurement with protection
Multiple Load Connection Can drive multiple loads concurrently Eliminates need for multiple transformers
Instrumentation Support Sufficient capacity for panel meters, recorders, and protection relays Comprehensive monitoring and protection in single transformer
Revenue Metering High capacity for billing-grade meters Accurate revenue metering with adequate burden capacity
SCADA Integration Supports data acquisition systems Enables remote monitoring and control
Future Expansion Excess capacity for additional loads Flexibility for system upgrades
Cost-Effective Single high-capacity transformer vs. multiple units Reduced equipment and installation costs
Phase-to-Phase vs Phase-to-Ground Feature JDZ9 Series (Phase-to-Phase) JDZX9 Series (Phase-to-Ground)
Measurement Type Phase-to-phase voltage (line-to-line) Phase-to-ground voltage (line-to-neutral)
Primary Voltage 3kV, 6kV, 10kV 3kV/√3, 6kV/√3, 10kV/√3
Secondary Voltage 100V 100V/√3 (metering) + 100V/3 (protection)
Protection Winding No Yes (100V/3 winding for 6P class protection)
Typical Application Phase-to-phase voltage measurement Phase-to-ground measurement + relay protection
System Compatibility All grounding systems Ungrounded or resonant grounded systems
VKV Compatibility Yes (Same as VKV) No
JDZ9-10Q with dual secondary windings (10 kV / 100 V + 100 V)
Accuracy Class Combination Winding 1 Burden (VA) Winding 2 Burden (VA) Max Output (VA) Application
0.2/0.2 20 20 400/400 Dual high-precision revenue metering
0.2/0.5 20 30 400/400 High-precision metering + standard monitoring
0.5/0.5 30 30 400/400 Dual standard metering applications
JDZX9-10G with three secondary windings (10 kV/√3 / 100 V/√3 + 100 V/√3 + 100 V/3)
Accuracy Class Combination Winding 1 Burden (VA) Winding 2 Burden (VA) Protection Winding (VA) Max Output (VA) Application
0.2/0.2 15 15 400/400 Dual high-precision metering
0.2/0.5 15 20 400/400 High-precision metering + standard monitoring
0.5/0.5 40 40 400/400 Dual standard metering
6P 100 Relay protection winding
JDZ9-3Q(3kV)
Accuracy Class Burden Capacity (VA) Max Output (VA) Application
500 High output capacity for 3kV systems (VKV compatible)
JDZ9-6Q(6kV)
Accuracy Class Burden Capacity (VA) Max Output (VA) Application
0.2 40 500 High-precision revenue metering for 6kV systems
0.5 100 500 Standard metering and monitoring for 6kV systems
1 200 500 General voltage monitoring for 6kV systems
3 240 500 Monitoring and instrumentation for 6kV systems
JDZ9-10Q(10kV)
Accuracy Class Burden Capacity (VA) Max Output (VA) Application
0.2 40 500 High-precision revenue metering for 10kV systems
0.5 100 500 Standard metering and monitoring for 10kV systems
1 200 500 General voltage monitoring for 10kV systems
3 240 500 Monitoring and instrumentation for 10kV systems
JDZX9-6G(6kV/√3)
Accuracy Class Burden Capacity (VA) Max Output (VA) Application
0.2 30 600 High-precision phase-to-ground metering for 6kV systems
0.5 60 600 Standard phase-to-ground monitoring for 6kV systems
1 180 600 General phase-to-ground voltage monitoring for 6kV systems
3 500 600 Monitoring and instrumentation for 6kV systems
6P 100 600 Relay protection applications for 6kV systems
JDZX9-10G(10kV/√3)
Accuracy Class Burden Capacity (VA) Max Output (VA) Application
0.2 30 600 High-precision phase-to-ground metering for 10kV systems
0.5 60 600 Standard phase-to-ground monitoring for 10kV systems
1 180 600 General phase-to-ground voltage monitoring for 10kV systems
3 500 600 Monitoring and instrumentation for 10kV systems
6P 100 600 Relay protection applications for 10kV systems
Epoxy Resin Casting Feature Description Benefit
Solid Insulation Epoxy resin casting provides solid insulation No oil leakage, environmentally friendly
Superior Moisture Resistance Epoxy resin is highly moisture resistant Reliable operation in humid environments
Flame Retardancy Self-extinguishing flame retardant properties Enhanced fire safety
Maintenance-Free Solid insulation requires no maintenance Reduced operational costs and downtime
Environmental Protection No oil, no pollution Eco-friendly and safe for indoor use
Compact Design Smaller footprint than oil-immersed types Ideal for space-constrained indoor switchgear
Long Service Life Epoxy resin does not age like oil Extended operational life (30+ years)
High Mechanical Strength Robust epoxy resin construction Excellent vibration and shock resistance
Excellent Dielectric Properties High dielectric strength Reliable high voltage insulation
No Explosion Risk Solid insulation eliminates explosion hazard Enhanced safety for indoor installations
JDZ9-3Q/JDZX9-3G(3kV) Insulation Level
Insulation Level Lightning Impulse Withstand Power Frequency Withstand Application Environment
3.6kV Rated voltage level Short-duration power frequency Standard 3kV systems
25kV Lightning impulse Medium-duration withstand Lightning protection requirements
40kV Full lightning impulse Full insulation withstand Maximum insulation protection
JDZ9-6Q/JDZX9-6G(6kV) Insulation Level
Insulation Level Lightning Impulse Withstand Power Frequency Withstand Application Environment
7.2kV Rated voltage level Short-duration power frequency Standard 6kV systems
32kV Lightning impulse Medium-duration withstand Lightning protection requirements
60kV Full lightning impulse Full insulation withstand Maximum insulation protection
JDZ9-10Q/JDZX9-10G(10kV) Insulation Level
Insulation Level Lightning Impulse Withstand Power Frequency Withstand Application Environment
12kV Rated voltage level Short-duration power frequency Standard 10kV systems
42kV Lightning impulse Medium-duration withstand Lightning protection requirements
75kV Full lightning impulse Full insulation withstand Maximum insulation protection
Application Scenario Recommended Model Key Advantage Typical Installation
3kV Phase-to-Phase Measurement JDZ9-3Q 500VA high output for 3kV phase-to-phase applications (VKV compatible) 3kV indoor switchgear
6kV Phase-to-Phase Measurement JDZ9-6Q 500VA output for 6kV phase-to-phase applications (VKV compatible) 6kV indoor switchgear, industrial facilities
10kV Phase-to-Phase Measurement JDZ9-10Q 500VA output for 10kV phase-to-phase applications (VKV compatible) 10kV indoor switchgear, distribution substations
10kV Dual Phase-to-Phase Metering JDZ9-10Q (Dual) Dual 100V secondaries for independent metering (400/400VA) Billing + monitoring applications
3kV Phase-to-Ground + Protection JDZX9-3G Phase-to-ground measurement with 100V/3 protection winding 3kV ungrounded systems
6kV Phase-to-Ground + Protection JDZX9-6G 600VA output for phase-to-ground measurement + 6P protection 6kV ungrounded or resonant grounded systems
10kV Phase-to-Ground + Protection JDZX9-10G 600VA output for phase-to-ground measurement + 6P protection 10kV ungrounded or resonant grounded systems
10kV Dual Metering + Protection JDZX9-10G (Triple) Triple secondary: dual metering + protection (400/400VA) Critical systems requiring redundancy
Indoor Substations JDZ(X)9 Series Epoxy resin casting eliminates oil leakage concerns Indoor distribution substations
Commercial Buildings JDZ9-6Q/10Q Compact, safe, maintenance-free, high capacity Shopping malls, office buildings
Industrial Facilities JDZX9-6G/10G Phase-to-ground measurement + protection for ungrounded systems Manufacturing plants, industrial parks
SCADA Systems JDZ(X)9 Series 500-600VA capacity supports data acquisition systems Remote monitoring and control applications
Feature JDZ9 Series (Phase-to-Phase) JDZX9 Series (Phase-to-Ground)
Measurement Type Phase-to-phase voltage Phase-to-ground voltage
Primary Voltage 3kV, 6kV, 10kV 3kV/√3, 6kV/√3, 10kV/√3
Secondary Voltage 100V 100V/√3 (metering) + 100V/3 (protection)
Maximum Output 500VA 600VA
Protection Winding No Yes (100V/3 for 6P class)
VKV Compatible Yes (Same as VKV) No
Key Advantage Phase-to-phase measurement with VKV compatibility Phase-to-ground measurement + relay protection
Typical Application Standard phase-to-phase voltage measurement Ungrounded systems requiring protection

 

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
🔒 Your information is secure and encrypted.
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact
🔒 Your information is secure and encrypted.