LZZBW-10 Support Type Current Transformer 10kV Outdoor Full-Enclosed CT – 10-1500A Multi-Ratio 0.2S/0.5/10P10/10P20 Class Swiss CIBA Epoxy Resin 12/42/75kV Pollution Class IV

Description:

LZZBW-10 Support Type Current Transformer 10kV Outdoor Full-Enclosed CT: 10-1500A primary current, 0.2S/0.5/10P10/10P20 accuracy class, multi-ratio configuration, Swiss CIBA CW5837 epoxy resin, 12/42/75kV insulation level, pollution class IV, 10-20VA burden, arc/UV/aging resistant, 5A/1A secondary, 50-60Hz, GB1208 IEC60044-1.

Applications:

Advanced LZZBW-10 Support Type Current Transformer: Outdoor single-phase support type full-enclosed epoxy resin casting CT conforming to GB1208-2006 and IEC185/IEC60044-1 standards, rated insulation level 12/42/75kV, rated frequency 50Hz or 60Hz, rated secondary current 5A or 1A, ambient temperature -5°C to +40°C, pollution class IV for harsh environments, rated primary current range 10-1500A with multi-ratio configurations providing exceptional flexibility, Swiss CIBA CW5837 outdoor-grade epoxy resin featuring electric arc resistance, ultraviolet ray resistance, aging resistance, long service life, large creepage distance, minimal partial discharge, and superior overvoltage withstand capability, flexible accuracy class combinations including 0.2S/0.5/10P10/10P20 with burden capacity 10-20VA, thermal current 2.7-80kA and dynamic current 4.5-160kA ensuring reliable short-circuit protection.

Superior Swiss CIBA Resin Technology and Multi-Ratio Flexibility: LZZBW-10 features premium Swiss CIBA CW5837 outdoor-grade epoxy resin providing exceptional environmental durability with arc/UV/aging resistance for extended outdoor service life, robust support type full-enclosed construction ensuring superior mechanical strength and pollution class IV performance in contaminated environments, innovative multi-ratio design offering flexible primary current selection (dual-ratio and triple-ratio configurations) without transformer replacement reducing inventory costs, suitable for 10kV switchgear, outdoor substations, power distribution systems, industrial power networks, coastal/polluted environments, and applications requiring reliable current measurement from 10A to 1500A with Swiss-quality epoxy resin technology and multi-ratio operational flexibility.

Specifications

LZZBW-10 Support Type Current Transformer 10kV Outdoor Full-Enclosed CT - 10-1500A Multi-Ratio 0.2S0.510P1010P20 Class Swiss CIBA Epoxy Resin 124275kV Pollution Class IV GB1208 IEC60044-1

Features

LZZBW-10 Current Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number LZZBW-10
Category Switchgear & HV CT (High Voltage Current Transformer)
Product Type 10kV Outdoor Single-Phase Support Type Full-Enclosed Epoxy Resin Casting Current Transformer with 10-1500A Range, Swiss CIBA CW5837 Resin, Multi-Ratio Configuration, 0.2S/0.5/10P10/10P20 Accuracy Class, 12/42/75kV Insulation, Pollution Class IV for Metering & Protection
Core Technology Outdoor Single-Phase Support Type Full-Enclosed Design + Swiss CIBA CW5837 Outdoor-Grade Epoxy Resin Casting + 10kV Design + Multi-Ratio Configuration (Dual-Ratio and Triple-Ratio Options) + GB1208-2006 and IEC185/IEC60044-1 Standards Compliant + Rated Insulation Level 12/42/75kV + Rated Frequency 50Hz or 60Hz + Rated Secondary Current 5A or 1A + Ambient Temperature -5°C to +40°C + Pollution Class IV + Rated Primary Current Range 10-1500A + Ultra-Wide Current Coverage + Electric Arc Resistance + Ultraviolet Ray Resistance + Aging Resistance + Long Service Life + Large Creepage Distance + Minimal Partial Discharge + Superior Overvoltage Withstand Capability + Flexible Accuracy Classes (0.2S/0.5/10P10/10P15/10P20) + Burden Capacity 10-20VA + Thermal Current 2.7-80kA + Dynamic Current 4.5-160kA + Reliable Short-Circuit Protection + Robust Support Type Full-Enclosed Outdoor Construction
Power (Voltage) 10kV
Rated Voltage 10kV
Rated Insulation Level 12/42/75 kV
Rated Frequency 50Hz or 60Hz Hz
Rated Secondary Current 5A or 1A A
Rated Primary Current Range 10-1500 A
Ambient Temperature -5°C to +40°C °C
Pollution Class IV (Class 4)
Structure Type Outdoor Single-Phase Support Type Full-Enclosed Epoxy Resin Casting
Epoxy Resin Type Swiss CIBA CW5837 Outdoor-Grade
Voltage Level Medium Voltage (10kV)
Installation Type Outdoor Support Type
Phase Single Phase
Standards Compliance GB1208-2006 and IEC185/IEC60044-1
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Swiss CIBA Epoxy Resin Yes (Swiss CIBA CW5837 Outdoor-Grade Epoxy Resin)
10kV Design Yes (10kV Rated Voltage)
Support Type Full-Enclosed Yes (Support Type Full-Enclosed Outdoor Construction)
Multi-Ratio Configuration Yes (Dual-Ratio and Triple-Ratio Options)
Pollution Class IV Yes (Pollution Class IV for Harsh Environments)
Arc Resistance Yes (Electric Arc Resistance)
UV Resistance Yes (Ultraviolet Ray Resistance)
Aging Resistance Yes (Aging Resistance for Long Service Life)
Large Creepage Distance Yes (Large Creepage Distance for Pollution Environments)
Minimal Partial Discharge Yes (Little Partial Discharge)
Superior Overvoltage Withstand Yes (Superior Overvoltage Withstand Capability)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
10kV Rated Voltage Yes (Rated Voltage 10kV)
GB1208-2006 Compliant Yes (In Accordance with GB1208-2006 Standard)
IEC185 Compliant Yes (In Accordance with IEC185 Standard)
IEC60044-1 Compliant Yes (In Accordance with IEC60044-1 Standard)
12/42/75kV Insulation Yes (Rated Insulation Level 12/42/75kV)
5A or 1A Secondary Yes (Rated Secondary Current 5A or 1A)
-5°C to +40°C Ambient Yes (Ambient Temperature -5°C to +40°C)
10-1500A Primary Range Yes (Rated Primary Current Range 10-1500A)
Ultra-Wide Current Coverage Yes (From 10A to 1500A Primary Current)
0.2S Accuracy Class Yes (0.2S Metering Accuracy Class Available)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5S Accuracy Class Yes (0.5S Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
10P10 Protection Class Yes (10P10 Protection Accuracy Class Available)
10P15 Protection Class Yes (10P15 Protection Accuracy Class Available)
10P20 Protection Class Yes (10P20 Protection Accuracy Class Available)
10-20VA Burden Capacity Yes (Burden Capacity 10-20VA)
Main Technical Parameters
Rated primary current (A) Accuracy classes combination Rated output (VA) 1s thermal current (kA) Rated dynamic current (kA)
20–40;40 0.2 / 0.5 10 / 10 6.3 15
30–50;50 0.5S / 0.5 10 / 10 7.5 18.75
40–75;75 0.5 / 0.5 10 / 10 15 37.5
50–100;100 0.2 / 0.5 10 / 10 18 45
75–150;150 0.2 / 10P10 10 / 15 25 55
100–200;200 0.5 / 10P10 10 / 15 50 110
150–300;300 10P10 / 10P10 10 / 15 60 130
200–400;400 10P15 / 10P15 10 / 10 60 130
300–600;600 10P20 / 10P20 10 / 10 60 130
400–800;800 0.2S / 0.5 / 10P10 10 / 15 / 15 60 130
500–1000;1000 0.2S / 0.5 / 10P20 15 / 15 / 20 80 160
1200–1500;1500 0.2S / 0.5 / 10P20 15 / 15 / 20 80 160
Complex Variable Technique Parameters
Rated primary current (A) Accuracy classes combination Rated secondary output (VA) 1s thermal current (kA) Rated dynamic current (kA)
10–15–20 0.2 / 0.2 10 / 10 2.7 4.5
15–20–30 0.2 / 0.5 10 / 10 4.2 6.6
20–30–40 0.5 / 0.5 10 / 10 6 9
30–40–50 0.2 / 10P10 10 / 15 9 11.5
40–50–75 0.5 / 10P10 10 / 15 11.3 16.5
50–75–100 0.2S / 0.5 / 10P10 10 / 10 / 15 16.8 22
75–100–150 0.2S / 0.5 / 10P10 10 / 10 / 15 24 33
100–150–200 0.2S / 0.5 / 10P10 10 / 10 / 15 33.6 45
150–200–300 0.2S / 0.5 / 10P20 / 10P20 15 / 15 / 20 / 20 45 63
200–300–400 0.2S / 0.5 / 10P20 / 10P20 15 / 15 / 20 / 20 45 80
300–400–500 0.2S / 0.5 / 10P20 / 10P20 15 / 15 / 20 / 20 45 100
500–600–800 0.2S / 0.5 / 10P20 / 10P20 15 / 15 / 20 / 20 80 130
600–800–1000 0.2S / 0.5 / 10P20 / 10P20 15 / 15 / 20 / 20 80 130
Ratio Configuration Primary Current Options Flexibility Advantage Typical Application
Dual-Ratio (20-40; 40) Two ratio options Flexible current selection without replacement Small to medium load applications
Dual-Ratio (30-50; 50) Two ratio options Flexible current selection Medium load applications
Triple-Ratio (10-15-20) Three ratio options Maximum flexibility for low current Small load distribution networks
Triple-Ratio (50-75-100) Three ratio options Maximum flexibility for medium current Medium load distribution networks
Triple-Ratio (150-200-300) Three ratio options Maximum flexibility for high current High load distribution networks
Triple-Ratio (600-800-1000) Three ratio options Maximum flexibility for very high current Very high load distribution networks
Swiss CIBA CW5837 Resin Feature Description Benefit
Electric Arc Resistance Superior arc resistance Prevents surface tracking and flashover
Ultraviolet Ray Resistance UV-resistant formulation Prevents degradation from sunlight exposure
Aging Resistance Long-term stability Extended service life in outdoor environments
Large Creepage Distance Enhanced surface insulation Superior performance in polluted environments
Minimal Partial Discharge Low partial discharge levels Improved insulation reliability
Superior Overvoltage Withstand High overvoltage capability Enhanced protection against voltage surges
Swiss Quality Premium Swiss CIBA CW5837 World-class reliability and performance
Pollution Class Description Typical Environment Application
Class IV Very heavy pollution Industrial areas, coastal regions, desert areas Heavy industrial facilities, coastal substations, polluted environments
Accuracy Class Combination Application Current Range Burden Capacity
0.2/0.2 Dual high-precision metering 10-40A 10/10VA
0.2/0.5 High-precision metering + standard metering 10-100A 10/10VA
0.5S/0.5 Dual standard metering 30-50A 10/10VA
0.5/0.5 Dual standard metering 20-75A 10/10VA
0.2/10P10 High-precision metering + protection 30-150A 10/15VA
0.5/10P10 Standard metering + protection 40-200A 10/15VA
10P10/10P10 Dual protection 150-300A 10/15VA
10P15/10P15 Dual protection (higher accuracy limit) 200-400A 10/10VA
10P20/10P20 Dual protection (highest accuracy limit) 300-600A 10/10VA
0.2S/0.5/10P10 Triple function (high-precision + standard + protection) 50-800A 10/15/15VA
0.2S/0.5/10P20 Triple function (high-precision + standard + high protection) 150-1500A 15/15/20VA
0.2S/0.5/10P20/10P20 Quadruple function (maximum flexibility) 150-1000A 15/15/20/20VA
Current Range Thermal Current (kA) Dynamic Current (kA) Thermal/Dynamic Ratio Application
10-20A 2.7 4.5 1.67:1 Low current with standard protection
15-30A 4.2 6.6 1.57:1 Low-medium current with standard protection
20-100A 6-18 9-45 ~2.5:1 Medium current with high protection
75-300A 25-60 55-130 ~2.2:1 Medium-high current with enhanced protection
300-800A 60 130 2.17:1 High current with maximum protection
500-1500A 80 160 2:1 Very high current with maximum capacity

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
🔒 Your information is secure and encrypted.
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact
🔒 Your information is secure and encrypted.