GW1 Outdoor AC HV Disconnect Switch 12-40.5kV 630-1250A – Three-Pole Linkage IEC62271-103 Anti-Pollution Type 50/60Hz 20-25kA 2000 Life
GW1 Outdoor AC HV Disconnect Switch 12-40.5kV 630-1250A: Three-pole linkage, IEC62271-103 compliant, anti-pollution type, 50/60Hz, good synchronous performance, 20-25kA withstand, 50-63kA peak, 2000 mechanical life, 3000m altitude, -30°C to +40°C, 35m/s wind, Class IV pollution, 10mm ice.
GW4 Outdoor HV Disconnector 12-40.5kV 200-1250A – Fixed Draw Hook Self-Locking Insulating Hook-Stick Anti-Pollution Type Class IV 16-31.5kA
GW4 Outdoor HV Disconnector 12-40.5kV 200-1250A: Fixed draw hook, self-locking device, insulating hook-stick operation, anti-pollution type, Class IV pollution level, 16-31.5kA withstand, 40-80kA peak, 3000m altitude, -40°C to +40°C, 35m/s wind speed, earthquake degree 8.
GN38-12 Indoor HV Disconnecting Switch 12kV 630-1250A – Three-Position Compact Box Switchgear Fully Insulated Baseplate Coaxial Locking 25-31.5kA
GN38-12 Indoor HV Disconnecting Switch 12kV 630-1250A: Three-position structure, compact box switchgear, fully insulated baseplate, coaxial locking, mechanical interlocking, small-sized design, 25-31.5kA thermal stability, 63-80kA dynamic current, 42kV/48kV frequency withstand, 75kV/85kV impulse.
GN27-40.5 Indoor HV Isolating Switch 40kV 630-1250A – Vertical Rotating Blade CS6-2 Manual CX6 Electric 10-110kV Power System No-Load Circuit
GN27-40.5 Indoor HV Isolating Switch 40kV 630-1250A: Three-phase AC 50Hz, vertical rotating blade, CS6-2 manual/CX6 electric mechanism, 10-110kV power system, no-load circuit breaking, swing-type multi-contact, 20-31.5kA withstand, 50-80kA peak, 185kV/215kV impulse, 95kV/115kV frequency.
GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A – Three-Phase Cabinet Mounted IEC62271-102 No-Load Transfer Switch 4s Duration
GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A: Three-phase AC 50/60Hz, rotary moving contact, cabinet mounted, wall through installation, IEC62271-102 compliant, no-load transfer, 12.5-40kA withstand, 31.5-100kA peak, 42kV/49kV frequency withstand, 75kV/85kV impulse.
GN24-12 Indoor HV Disconnect Switch 12kV 400A-1250A – Three-Pole Type No-Load Breaking Pollution Abatement High Altitude Electrified Display 2000 Life
GN24-12 Indoor HV Disconnect Switch 12kV 400A-1250A: Three-pole type, no-load breaking, pollution abatement type, high altitude type, electrified display, 2000 mechanical life, 20kA short-time withstand, 50kA peak withstand, porcelain insulator, 1000-3000m altitude, -30°C to +40°C.
GN19-12 Indoor High Voltage Isolation Disconnector 12kV 630A-1250A – CS6-1 Manual Mechanism Through-Wall Type MV Switchgear 2000 Mechanical Life
GN19-12 Indoor High Voltage Isolation Disconnector 12kV 630A-1250A: CS6-1 manual mechanism, through-wall type C1/C2/C3, no-load breaking, 2000 mechanical life, 20kA short-time withstand, 50kA peak withstand, porcelain insulator, live display device, anti-pollution type.
ZW8-12 Outdoor 12kV MV Vacuum Circuit Breaker 630A – Permanent Magnet Mechanism Epoxy Resin Solid Insulation 10000 Mechanical Life Maintenance-Free
ZW8-12 Outdoor 12kV MV Vacuum Circuit Breaker 630A: Permanent magnet mechanism, epoxy resin solid insulation, 10000 mechanical life, maintenance-free, 20/25/31.5kA breaking current, small size, light weight, pollution-free, 10kV urban grid, -40°C to +40°C.
ZW39-40.5 Outdoor High Voltage Vacuum Circuit Breaker 35kV – CT10-A Spring Mechanism Frequent Operation Contact Breaker GB1984 IEC Compliant
ZW39-40.5 Outdoor High Voltage Vacuum Circuit Breaker: 35kV AC 50Hz, CT10-A improved spring mechanism, strong breaking capacity, low operating power, high reliability, frequent operation, contact circuit breaker, industrial/mining/power plants/substations, GB1984/GB/T11022/JB/T3855 compliant.
ZW30A-40.5 Outdoor High Voltage Vacuum Circuit Breaker 40.5kV – 10000 Mechanical Life SF6 Insulation 630A Capacitor Switching 12 CT Spring Mechanism
ZW30A-40.5 Outdoor High Voltage Vacuum Circuit Breaker: 40.5kV 10000 mechanical life, SF6 auxiliary insulation, 630A capacitor switching no re-ignition, spring mechanism remote control, up to 12 CT, out-of-step breaking, oil-free operation, frequent operation, power transmission/transformation.