LW3-12 Primary Secondary Fusion SF6 Circuit Breaker 12kV 630A – Smart Grid Distribution Automation Unified Protection CT
LW3-12 Primary Secondary Fusion SF6 Circuit Breaker: 12kV 630A smart grid, distribution automation, unified protection CT, zero-sequence CT/voltage sensor, high measurement accuracy, compact structure, -40°C to +50°C.
ZW32-40T Outdoor Disconnector Vacuum Circuit Breaker 40kV VCB 630A – Smart Recloser Isolating Switch Distribution Automation
ZW32-40T Outdoor Disconnector Vacuum Circuit Breaker: 40kV VCB 630A, combined with isolating switch, smart recloser, fault isolation, distribution automation, three-stage protection, electronic PT, silicone rubber sheath, -40°C to +40°C.
ZW32-40.5 Outdoor Vacuum Circuit Breaker 40kV VCB 630A – Smart Recloser Controller Fault Isolation Distribution Automation
ZW32-40.5 Outdoor Vacuum Circuit Breaker: 40kV VCB 630A smart recloser, controller with fault isolation, distribution automation, three-phase AC 50Hz, multiple auto reclosing, three-stage protection, electronic PT, -40°C to +40°C.
ZW32-24 Outdoor Vacuum Circuit Breaker 24kV VCB 3150A – Smart Recloser Controller Fault Isolation Distribution Automation
ZW32-24 Outdoor Vacuum Circuit Breaker: 24kV VCB 3150A smart recloser, controller with fault isolation, distribution automation, 40kA breaking, multiple auto reclosing, three-stage protection, electronic PT, -40°C to +40°C.
ZW32-12 Outdoor Vacuum Circuit Breaker 12kV MV VCB 4000A – Smart Recloser Controller Fault Isolation Distribution Automation
ZW32-12 Outdoor Vacuum Circuit Breaker: 12kV MV VCB 4000A smart recloser, controller with fault isolation, distribution automation, 40kA breaking, multiple auto reclosing, three-stage protection, electronic PT, -40°C to +40°C.
ZW20-12 Outdoor Vacuum Circuit Breaker 12kV VCB Recloser – Pole Mounted Auto Reclosing SF6 Distribution Automation
ZW20-12 Outdoor Vacuum Circuit Breaker: 12kV VCB recloser 1250A, pole mounted, auto reclosing, SF6 sealed, distribution automation, 20kA breaking, 10000 cycles, substation/urban network, frequent operation, -40°C to +40°C.
12kV Indoor Vacuum Circuit Breaker MV VCB 1250A – High Voltage Solid-Sealed Poles E2/M2 Life Frequent Operation
12kV Indoor Vacuum Circuit Breaker: MV VCB 1250A high voltage, solid-sealed poles, E2/M2 life, frequent operation, various loads switching, 31.5kA breaking, 10000 cycles, impact/dust/condensation protection, -15°C to +40°C.
ZN63A-12 VS1 Vacuum Circuit Breaker 12kV/24kV 4000A – Indoor High Voltage VCB Embedded Poles KYN28A Switchgear
ZN63A-12 VS1 Vacuum Circuit Breaker: 12kV/24kV 4000A indoor high voltage VCB, embedded poles, KYN28A/XGN switchgear, solid-sealed poles, E2/M2 life, free maintenance, 40kA breaking, 10000 cycles, -15°C to +40°C.
VJG(C)-12GD/24GD SF6-Free Vacuum Circuit Breaker – Three-Position VCB EU 2026 Compliant Air Insulated Switchgear
VJG(C)-12GD/24GD SF6-Free Vacuum Circuit Breaker: 12kV/24kV 1250A three-position VCB, EU 2026 compliant, air insulated switchgear, zero SF6, enclosed column, modular design, 10000 cycles, -25°C to +40°C.
LN2-40.5 SF6 Circuit Breaker 40.5kV 800A – Indoor High Voltage SF6 CB Frequent Operation Capacitor Bank Switching
LN2-40.5 SF6 Circuit Breaker: 40.5kV 800A indoor high voltage SF6 CB, frequent operation, capacitor bank switching, contactor circuit breaker, reinforced insulation, 2000m altitude, CT1017/19 mechanism, -25°C to +40°C.